background image

172001UA

2-3

I

Power

T

S

R

J3

C

Factory Test Straps

Must be Installed for Unit To

Operate Correctly

J1 (RS-232) Is a DTE, and
     MUST Connect to a
     Modem (DCE)
J2 (X.21) Is a DTE, and
     MUST Connect
     to a Modem (DCE)

J2

X.21

J1

RS-232

JP3

JP2

JP1

JP4

SW1

X.21 INTERFACE

DCE

DTE

Signal

to

Chassis

Ground

SW2

SW3

JP5

JP6

DTR /RTS

DCD / CTS

SW4

SW5

DCE

DTE

V.24 INTERFACE

Figure 3

  

(Factory Default Setting)

Equipment Grounding

JP4 provides grounding interconnection in those systems requiring a
connection between Frame Ground and Signal Ground. If signal ground
and chassis ground interconnection is desired, install the jumper on JP4.

LED Indicators

The Following LED indicators are provided for diagnostics: Power, Transmit
Data (T), Receive Data (R), Control (C), Indicate (I) and Signal Timing (S).

Factory Test Straps

The Factory Test Straps JP1, JP2 and JP3 must be installed for proper
operation of the interface converter.

Signal Crossover

JP5 controls selection of DTR or RTS as the active V.24 control signal.
JP6 controls selection of the DCD or CTS as the active V.24 control signal.
The selection of DTE or DCE on the two interfaces will determine which
X.21 signal is connected to which V.24 control signal.

Summary of Contents for 2021P

Page 1: ...NVERTER V 24 TO X 21 2021P CTS IC V 24 X 21 INSTALLATION AND OPERATIONS MANUAL Doc 172001UA Part 07M2021P A B February 21 2000 AnISO 9001 CertifiedCompany Copyright 2000 Patton Electronics Co All Righ...

Page 2: ...CHAPTER 2 SETUP AND INSTALLATION Installation 2 1 Selection of DTE DCE 2 1 Equipment Grounding 2 3 LED Indicators 2 3 Factory Test Straps 2 3 APPENDIX TECHNICAL SPECIFICATIONS A 1 X 21 Interface Pins...

Page 3: ...rate and use radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and television reception Th...

Page 4: ...devices is not supported because internal clocking is not provided by this device Devices can be separated up to 4000 feet away from the interface con verter on the balanced interface side and RS 232...

Page 5: ...d SW2 to the DCE position and SW3 SW4 and SW5 to the DTE position as shown in Fig 1 X 21 DCE V 24 DTE RXD 3 TXD 2 RXC 17 TXC 15 S 6 13 T 2 9 R 4 11 X 21 DTE V 24 DCE Buffer RTS 4 DTR 20 C 3 10 CTS 5 D...

Page 6: ...e Installed for Unit To Operate Correctly J1 RS 232 Is a DTE and MUST Connect to a Modem DCE J2 X 21 Is a DCE and MUST Connect to a Terminal DTE J2 X 21 J1 RS 232 JP3 JP2 JP1 JP4 SW1 X 21 INTERFACE DC...

Page 7: ...n Frame Ground and Signal Ground If signal ground and chassis ground interconnection is desired install the jumper on JP4 LED Indicators The Following LED indicators are provided for diagnostics Power...

Page 8: ...sical Interface Female DB 15 V 11 Connector DCE DTE Configuration Switch Selectable Enclosure Aluminum Shell or 1010R16 P UI CTS MCS 16C Card Rack Assembly Front Panel Indicators Power Transmit Data R...

Page 9: ...2 3 4 5 6 7 8 9 10 11 12 13 14 15 X 21 Interface Pins Supported 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Shield common Transmit Data from DTE Receive Data from DCE Request to...

Page 10: ...B Sales 301 975 1000 Support 301 975 1007 Web Address http www patton com 7622 Rickenbacker Drive Gaithersburg MD 20879...

Reviews: