background image

147001UA

CHAPTER 1 - Operation

The Patton 2020P (IC-V.24/V.35) is a RS-232 to V.35 interface con-
verter.  The interface converter operates bi-directionally. DCE / DTE
selection of the ports permits interfacing RS-232 terminals to V.35
Modems or RS-232 Modems to V.35 terminals.  This adapter is ideal for
High Speed Group Band Modems since it can operate at 56Kbps or
faster (Up to 128Kbps).

Because the operator can configure the interface converter to be RS-232
on the terminal port and V.35 on the Modem Port, or V.35 on the terminal
port and RS-232 on the Modem Port, the 2020P (IC-V.24/V.35) can
satisfy either interface conversion requirement.  Devices can be sepa-
rated up to 600 feet away from the 2020P (IC-V.24/V.35) on the V.35
side and RS-232 devices can be extended up to 50 feet away.  The unit
is supplied with a female DB-25 connector on the RS-232 port and a
female 34 pin connector on the CCITT V.35 port.

The Patton 2020P (IC-V.24/V.35) is housed in a sturdy aluminum enclo-
sure and has an internal 110/220VAC switch selectable power supply.
The Interface Converter will also fit into the 1010R16/P/UI (MCS-16C)
card rack assembly, providing a convienent means to us the cards in a
data center.

The unit has MET, c-MET and CE approvals and can operate on stan-
dard power found in most countries.

1-1

Typical Application

V.35 Host

Processor

V.24 Terminal

IC-V.24/V.35

Summary of Contents for 2020P

Page 1: ...VERTER V 24 TO V 35 2020P CTS IC V 24 V 35 M 34 INSTALLATION AND OPERATIONS MANUAL Doc 147001UA Part 07M2020P A May 11 2000 B An ISO 9001 Certified Company Copyright 2000 Patton Electronics Co All Rig...

Page 2: ...CHAPTER 2 SETUP AND INSTALLATION Installation 2 1 Selection of DTE DCE 2 1 Equipment Grounding 2 2 LED Indicators 2 2 Factory Test Straps 2 2 APPENDIX TECHNICAL SPECIFICATIONS A 1 V 35 Interface Pins...

Page 3: ...ception The Patton MSDs have been tested and found to comply with the limits for Class A computing devices in accordance with the specifications in Subpart J of Part 15 of FCC rules which are designed...

Page 4: ...35 can satisfy either interface conversion requirement Devices can be sepa rated up to 600 feet away from the 2020P IC V 24 V 35 on the V 35 side and RS 232 devices can be extended up to 50 feet away...

Page 5: ...for the line voltage in use prior to appling power to the 2020P IC V 24 V 35 Selection of DTE DCE To connect an RS 232 terminal type device DTE to a V 35 Modem type device DCE connect the terminal to...

Page 6: ...ct to a Modem DCE J2 V 35 Is a DCE and MUST Connect to a Terminal DTE Signal to Chassis Ground Equipment Grounding JP4 provides grounding interconnection in those systems requiring a connection betwee...

Page 7: ...0 to 10 000 feet Dimensions Height 2 00 inches 5 08cm Width 8 80 inches 21 08cm Length 9 80 inches 15 49cm Weight 2 25 lbs 1 02 Kg Applications RS 232 to CCITT V 35 interface conversion Capacity One...

Page 8: ...DCE Request to Send from DTE Clear To Send from DCE Data Set Ready from DCE Signal Ground common Data Carrier Detect from DCE Transmit Clock from DCE Receive Clock from DCE Data Terminal Ready from D...

Page 9: ...B Sales 301 975 1000 Support 301 975 1007 Web Address http www patton com 7622 Rickenbacker Drive Gaithersburg MD 20879...