5.2.2  REMOTE ANALOG LOOP

The second test mode is Remote Analog Loop.  To enter this

mode, set one of the Model 1070s (local) in test mode by depressing
the "Loopback Test" switch.  Any characters sent from the remote
Model 1070 will be returned back to the originating device (see Figure
6).  If no characters are echoed back, check the wiring between the two
Model 1070s.  Be sure to wire the units according to the instructions in
Section 4.0 Installation.

Figure 6.

Loopback Test Modes

RD

TD

TD

RD

Local 1070RC

In Normal Mode

Remote 1070RC

In Normal Mode

TX+

TX-

RX-

RX+

RX+

RX-

TX-

TX+

RD

TD

TD

RD

Local 1070RC

In Loopback Mode

Remote 1070RC

In Normal Mode

RX+

RX-

TX-

TX+

TX+

TX-

RX-

RX+

12

Local 1070

In Normal Mode

Remote 1070

In Normal Mode

Remote 1070

In Normal Mode

Local 1070

In Loopback Mode

5.0 OPERATION

Once you have properly configured and connected each Model

1070, simply plug in the AC power adapter to get them running;  there
is no power switch on the Model 1070.  You can monitor the operation
of the Model 1070 using the front panel LED indicators and built-in
loopback test modes. 

5.1  LED INDICATORS

The Model 1070 incorporates six front panel LEDs that show the

status of the modem:

1. The 

power

LED glows when AC power is applied to the modem.

2. The 

loopback test

LED glows when the loopback test switch

has been depressed and is in a test mode.

3.  The tri-state 

TD 

and 

RD

indicators blink red and green with data

activity.  Solid red indicates a low RS-232 logic level, and no color
indicates no activity on the line.  Note:  RS-232 devices idle in a low
state, so the LED will glow red if the connections are correct and the
RS-232 device is in an idle state.

4. The 

RTS

and 

CD

indicators glow red for a "low" signal and

green for a "high" signal.  Note:  RTS refers to the signal generated by
the DTE on pin 4.  CD refers to the signal generated by the Model 1070
on pin 8.  It also indicates that a signal is being received by the remote
modem.

5.2  LOOPBACK TEST MODES

Selected the test modes by depressing the "Loopback Test" switch.

When in loopback mode, the "Loopback Test" LED will glow red.   Two
tests are possible using this switch:  Local Analog Loop (LAL) and
Remote Analog Loop (RAL).

5.2.1  LOCAL ANALOG LOOP

The first test mode is Local Analog Loop (V.54 Loop 3).  Any data

sent to the local Model 1070 in the this mode will be echoed (returned)
back to the user device.  For example, characters typed on the
keyboard of a terminal will appear on the terminal screen (see Figure 6
on the following page).

11

Summary of Contents for 1070

Page 1: ...070 AC Powered Synchronous Short Range Modem Part 07M1070 C Doc 067011U Rev D Revised 1 22 08 C E R T I F I E D An ISO 9001 Certified Company SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 h...

Page 2: ......

Page 3: ...ntainer This number may be obtained from Patton Electronics Technical Service at 301 975 1007 http www patton com or support patton com NOTE Packages received without an RMA number will not be accepte...

Page 4: ......

Page 5: ...the Model 1070 s case for configuration The switches allow you to control line contention clocking methods RTS CTS delay and data rates Figures 1 and 2 below and Table 1 opposite page summarize the sw...

Page 6: ......

Page 7: ...raises CTS after a slight delay in order to give the remote terminal time to receive an incoming signal Depending on the type of environment either a 0 mS 8 mS or 53 mS delay can be selected Switch 6...

Page 8: ......

Page 9: ...RCV 3 XMT 4 XMT 5 RCV 6 GND For proper signal crossing between two Model 1070s using RJ 11 connectors pin out the twisted pair cable according to the diagram below The Model 1070 is not sensitive to...

Page 10: ......

Page 11: ...a multipoint topology you must configure the CARRIER ENABLE switch DIP switch 8 differently for the master Model 1070 than for the slave Model 1070 s Here are the proper DIP switch settings for a star...

Page 12: ......

Page 13: ...characters are echoed back check the wiring between the two Model 1070s Be sure to wire the units according to the instructions in Section 4 0 Installation Figure 6 Loopback Test Modes RD TD TD RD Lo...

Page 14: ......

Page 15: ...the potential of difficulties in the field we recommend that the cable used to connect the Model 1070s have a capacitance of no greater than 20pF ft and that the wire be no thinner than 26 AWG The Mod...

Page 16: ......

Page 17: ...APPENDIX D PATTON MODEL 1070 BLOCK DIAGRAM 16...

Page 18: ......

Page 19: ...ed 2 Poor quality twisted pair circuit 3 Poor twisted pair connections to Model 1070s 1 Check wiring between Model 1070 and connected DTE device it should be straight through 2 Compare your twisted pa...

Page 20: ......