background image

4.2  WIRING FOR MULTIPOINT CIRCUITS

The Model 1070 supports multi-point applications using either a

star or daisy chain topology.  Both topologies require special wiring, as
well as specific DIP switch settings for master and slave units.

4.2.1  DAISY CHAIN TOPOLOGY

Using a daisy chain topology, you may connect several Model

1070s together in a master/slave arrangement.  Maximum distance
between the units will vary based upon the number of drops, data rate,
wire gauge, etc.  Call Patton Technical Support for specific distance
estimates.

Figure 4 (below) shows how to wire the two-pair cables properly for

a Model 1070 daisy chain topology.  Note that the ground connection is
not needed.

In a multipoint topology, you must configure the CARRIER

ENABLE switch (DIP switch 8) differently for the master Model 1070
than for the slave Model 1070(s).  Here are the proper DIP switch
settings for a daisy chain topology:

Switch Number

8

Master Positions

OFF

Slave Positions

ON

9

HOST

FIRST SLAVE

OTHER SLAVE(S)

XMT

RCV

RCV

XMT

RCV

RCV

RCV

XMT

XMT

RCV

XMT

XMT

Figure 4.

Model 1070 daisy chain wiring

4.2.2  STAR TOPOLOGY

In a star topology, you may connect several Model 1070s together

in a master/slave arrangement.  Maximum distance between the units
will vary based upon the number of drops, data rate, wire gauge, etc.
Call Patton Technical Support for specific distance estimates.

Figure 5 (below) shows how to wire the two-pair cables properly for

a Model 1070 star topology.  Note that the ground connection is not
needed.

In a multipoint topology, you must configure the CARRIER

ENABLE switch (DIP switch 8) differently for the master Model 1070
than for the slave Model 1070(s).  Here are the proper DIP switch
settings for a star topology:

Switch Number

8

Master Positions

OFF

Slave Positions

ON

4.2  RS-232 CONNECTION 

To connect the Model 1070 to data terminal hardware (PC, host,

terminal, etc.), use a 

straight through

RS-232 cable.  To connect the

Model 1070 to data communications hardware (modem, multiplexer,
etc.), use a 

null modem

RS-232 cable.

HOST

FIRST SLAVE

SECOND SLAVE

XMT

RCV

RCV

XMT

RCV

RCV

RCV

XMT

XMT

RCV

XMT

XMT

Figure 5.

Model 1070 star wiring

10

Summary of Contents for 1070

Page 1: ...070 AC Powered Synchronous Short Range Modem Part 07M1070 C Doc 067011U Rev D Revised 1 22 08 C E R T I F I E D An ISO 9001 Certified Company SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 h...

Page 2: ......

Page 3: ...ntainer This number may be obtained from Patton Electronics Technical Service at 301 975 1007 http www patton com or support patton com NOTE Packages received without an RMA number will not be accepte...

Page 4: ......

Page 5: ...the Model 1070 s case for configuration The switches allow you to control line contention clocking methods RTS CTS delay and data rates Figures 1 and 2 below and Table 1 opposite page summarize the sw...

Page 6: ......

Page 7: ...raises CTS after a slight delay in order to give the remote terminal time to receive an incoming signal Depending on the type of environment either a 0 mS 8 mS or 53 mS delay can be selected Switch 6...

Page 8: ......

Page 9: ...RCV 3 XMT 4 XMT 5 RCV 6 GND For proper signal crossing between two Model 1070s using RJ 11 connectors pin out the twisted pair cable according to the diagram below The Model 1070 is not sensitive to...

Page 10: ......

Page 11: ...a multipoint topology you must configure the CARRIER ENABLE switch DIP switch 8 differently for the master Model 1070 than for the slave Model 1070 s Here are the proper DIP switch settings for a star...

Page 12: ......

Page 13: ...characters are echoed back check the wiring between the two Model 1070s Be sure to wire the units according to the instructions in Section 4 0 Installation Figure 6 Loopback Test Modes RD TD TD RD Lo...

Page 14: ......

Page 15: ...the potential of difficulties in the field we recommend that the cable used to connect the Model 1070s have a capacitance of no greater than 20pF ft and that the wire be no thinner than 26 AWG The Mod...

Page 16: ......

Page 17: ...APPENDIX D PATTON MODEL 1070 BLOCK DIAGRAM 16...

Page 18: ......

Page 19: ...ed 2 Poor quality twisted pair circuit 3 Poor twisted pair connections to Model 1070s 1 Check wiring between Model 1070 and connected DTE device it should be straight through 2 Compare your twisted pa...

Page 20: ......