3.2  RACK CARD INSTALLATION

 

The VLINK modem rack card comprised a front card and a rear card.Do 
the following to install the cards into the rack chassis:

   1. Slide the rear card into the back of the chassis along the metal rails.

   2. Secure the rear card using the supplied metal screws.

   3. Slide the front card into the chassis until you feel resistance as the 

front card engages the rear card. When that happens, 

 

gently 

 

push 

the front card forward until it is fully seated in the card-edge recepta-
cle of the rear card (it should 

 

click

 

 into place).

   4. Secure the front card using the captive fasteners.

 

Note

 

The Model 1001R14 chassis supports “hot swapping” of cards, 

so it is not necessary to power down the rack when you install or 
remove a VLINK modem rack card.

 

Figure 3. 

 

VLINK modem rack card

 

   5. Connect the line interface between the units (refer to section 3.3, 

“Connecting the Twisted-Pair Line Interface” on page 10)

 

Note

 

See Figure 3 for the rack card’s panel arrangements.

VDSL Link

Ether

net

PO

TS/ISDN

1068RC

Ethernet

Port

POTS/ISDN

Port

VDSL Link

RJ-45 interface

VDSL Link

terminal block

Summary of Contents for 1068

Page 1: ...USER MANUAL VLINK MODEM Model 1068 and 1058 SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 Part 07M1068 UM Doc 05816U2 001 Rev A Revised 10 17 06 An ISO 9001Certified Company...

Page 2: ...on 13 4 1 Configuring the hardware DIP switches 13 4 2 Configuring DIP Switch S1 15 Switch S1 1 Ethernet Auto Sense 15 Switches S1 2 and S1 4 Data Rate 15 5 0 Operation 17 5 1 Power Up 17 5 2 Front Pa...

Page 3: ...3 Terminal Block 1068DV TB45 Only 24 C 3 POTS ISDN Interface 24 RJ 45 24 D Distance Chart Based on 24 AWG 0 5 MM 25...

Page 4: ...is equipment generates and uses radio frequency energy and if not installed and used properly that is in strict accordance with the manu facturer s instructions may cause interference to radio and tel...

Page 5: ...This device is NOT intended nor approved for connec tion to the PSTN It is intended only for connection to customer premise equipment WARNING This device contains no user serviceable parts The equipm...

Page 6: ...onditioned lines Switch selectable line rates up to 16 67 Mbps 7 symmetric or asymmetric settings via DIP switch POTS ISDN splitter on board Transparent operation LED indicators for Power Ethernet Lin...

Page 7: ...units can automatically forward LAN broadcasts multicasts and frames across a 2 wire voice grade twisted pair link The data is passed transparently unmodified through the VLINK modems The VLINK modem...

Page 8: ...o section 3 3 Connecting the Twisted Pair Line Interface on page 10 Note See Figure 2 for the standalone unit s rear panel arrangements 2 Connect the Ethernet interface refer to section 3 4 Connecting...

Page 9: ...rd until it is fully seated in the card edge recepta cle of the rear card it should click into place 4 Secure the front card using the captive fasteners Note The Model 1001R14 chassis supports hot swa...

Page 10: ...powered on the CP can establish a link by being pow ered on or by having its power reset 1 To function properly the two VLINK modems must be connected together using twisted pair unconditioned dry me...

Page 11: ...10 100Base T interface This port is designed to connect directly to a 10 100Base T network Figure 6 shows the signal pin relationships on this interface You may connect this port to a hub or PC using...

Page 12: ...the power supply See Appen dix B for domestic and international power supply and cord options DC power supplied via the power supply jack to the VLINK modem must meet the following requirements DC pow...

Page 13: ...ins the different configurations No dip switch options are available on the 1058 4 1 CONFIGURING THE HARDWARE DIP SWITCHES Using a small flat tip screwdriver remove the protective cover located on the...

Page 14: ...rientation Figure 10 Model 1068 rack card DIP switch orientation Power VLINK Modem Link QOL VLINK Link Activity Ethernet 1 2 3 4 ON Push toggle to left for ON position Switch toggle Push toggle to rig...

Page 15: ...on only auto sensing for 100BaseT half duplex 10BaseT full duplex and 10BaseT half duplex The limited auto negotia tion feature is used when an Ethernet device does not comply with IEEE 802 3x back pr...

Page 16: ...ine Rates DS US DS downstream US upstream Note Table 3 only applies to Model 1068 OFF OFF ON 4 17 Mbps 1 56 Mbps OFF ON ON 9 38 Mbps 1 56 Mbps OFF ON OFF 16 67 Mbps 2 34 Mbps Table 4 Reserved for futu...

Page 17: ...power the Ethernet signals and the VDSL connection Figure 11 standalone version and Figure 12 on page 19 rack card ver sion show the front panel LEDs Table 5 on page 18 describes the LED functions fo...

Page 18: ...tly over the link even if the link is solidly yellow However if the LED is solid yellow and the VLINK Link LED is Off Off when no power is applied to the unit Ethernet Link On green when the 10 100Bas...

Page 19: ...rrupted data to the Ethernet port The more error corrections the more often the LED blinks If the light remains lit continuously it means that the VDSL line is noisy although the data at the Ethernet...

Page 20: ...ic Line Rate 12 5 Mbps Model 1068 Symmetric Line Rates 6 25 Mbps 9 38 Mbps 12 5 Mbps 16 67 Mbps Model 1068 Asymmetric Line Rates 4 17 Mbps 1 56 Mbps 9 38 Mbps 1 56 Mbps 16 67 Mbps 2 34 Mbps A 4 VDSL D...

Page 21: ...d DC options AC 120 VAC 220 VAC and UI 120 240 VAC DC 12 VDC 24 VDC and 48 VDC A 8 TEMPERATURE RANGE 32 122 F 0 50 C A 9 HUMIDITY Up to 90 non condensing A 10 DIMENSIONS 1 58H x 4 16W x 3 75D in 10 6H...

Page 22: ...ta 120 240VAC 1068DV CO TB45 EUI Variable Rate VDSL CO Modem voice and data TB and RJ45 120 240VAC 1068DV CP TB45 EUI Variable Rate VDSL CP Modem voice and data TB and RJ45 120 240VAC 1068DV CP TB45 E...

Page 23: ...American Power Cord 0805EUR European Power Cord CEE 7 0805UK United Kingdom Power Cord 0805AUS Australian Power Cord 0805DEN Denmark Power Cord 0805FR France Belgium Power Cord 0805IN India Power Cord...

Page 24: ...RX Pin 2 TX RX Pin 3 RX TX Pin 6 RX TX Pins 4 5 7 8 no connection C 2 VDSL INTERFACE RJ 45 Pin 4 RING Pin 5 TIP Pins 1 2 3 6 7 8 no connection Terminal Block 1068DV TB45 Only See Figure 5 on page 11 C...

Page 25: ...ate Distance in feet km 6 25 Mbps 4 500 1 37 9 38 Mbps 4 150 1 26 12 5 Mbps This is the only option available for Model 1058 4 000 1 22 16 67 Mbps 3 300 1 00 Asymm Line Rate DS US Distance in feet km...

Page 26: ..._________________ _________________________________________________________ _________________________________________________________ _________________________________________________________ ________...

Page 27: ...27 Copyright 2006 Patton Electronics Company All Rights Reserved...

Reviews: