8
3.0 INSTALLATION
Because the VLINK modem requires no configuration, it can be installed
quickly. If you are installing a standalone unit, refer to section 3.1 “Standal-
one unit installation”. Otherwise, refer to section 3.2 “Rack card installation”.
Note
If asymmetric transmission or line rates other than 12.5 Mbps
are required, refer to section 4.0, “Configuration” on page 13.
3.1 STANDALONE UNIT INSTALLATION
Do the following:
1. Connect the line interface between the units (refer to section 3.3,
“Connecting the Twisted-Pair Line Interface” on page 10)
Note
See Figure 2 for the standalone unit’s rear panel arrangements.
2. Connect the Ethernet interface (refer to section 3.4, “Connecting the
10/100Base-T Ethernet Interface” on page 11).
3. Connect the power plug (refer to section 3.6, “Connecting Power” on
page 12).
Figure 2.
VLINK modem standalone rear panel
Note
The VDSL twisted-pair terminal block interface is included on
Model 1068DV/TB45 only.
VDSL twisted-pair
terminal block
interface
Po
we
r
Made in the USA
Power
jack
VLINK Data & Voice
1068
Ether
net
PO
TS/ISDN
Line
POTS/ISDN twisted-pair
terminal block interface
VDSL twisted-pair
RJ-45 interface
Ethernet
port