5.4.2  REMOTE DIGITAL LOOPBACK (RDL)

The Remote Digital Loopback (RDL) test checks the performance

of both the local and remote Model 1065RCs, 

and the communication

link between them. Any characters sent to the remote 1065RC in this
test mode will be returned back to the originating device. For example,
characters typed on the keyboard of the local terminal will appear on
the local terminal screen 

after having been passed to the remote

Model 1065RC and looped back. To perform an RDL test, follow these
steps:

1.

Activate RDL. This may be done in two ways: by moving the
upper front panel toggle switch LEFT to “Remote” or by raising
pin 21 on the RS-232 interface.

2.

Verify that the DTE equipment on the local end is operating
properly and can be used for a test.

3.

Locate the lower of the two toggle switches on the front panel
of the 1065RC and move it to the right. This will activate the
V.52 BER test mode and inject a “511” test pattern into the
remote loop. If any errors are present in the loop, the red
“Error” LED will blink sporadically.

4.

If the BER test indicates 

no errors are present,  move the

V.52 toggle switch to the left, thus activating the “511/E” test
with periodic errors. If the test is working properly, the red
“Error” LED will blink

regularly. A successful “511/E” test will

confirm that the loop is in place, and that the Model 1065RC’s
built-in “511” generator and detector are working properly.

5.

If the remote BER test indicates that errors 

are present, and

the local analog loopback/BER tests showed that both Model
1065RCs were functioning properly, this suggests a problem
with the twisted pair communication line connecting the two
modems. A common problem is improper crossing of the
pairs. Also, verify that the modular connections are pinned
properly, and the twisted pair line has continuity. If you still
have errors, call Technical Support at (301) 975-1007.

5.4.3  USING THE V.52 BER TEST INDEPENDENTLY

The Model 1065RC's V.52 BER test can be used independent of

the V.54 loopback tests. This requires two operators: one to initiate and
monitor the test at both the local and the remote Model 1065RC. To
use the V.52 BER test by itself, both operators should simultaneously
follow these steps:

1.

Locate the lower of the two toggle switches on the front panel
of the Model 1065RC and move it to the right. This will acti-
vate the V.52 BER test mode and transmit a “511” test pattern
to the other unit. If any errors are present, the receiving
modem’s red “Error” LED will blink sporadically. Note: For this
independent test to function, the “511” switch on 

both Model

1065RCs must be turned on.

2.

If the test indicates no errors are present, move the V.52 tog-
gle switch to the left, thus activating the “511/E” test with peri-
odic errors present. If the test is working properly, the receiv-
ing modem’s red “Error” LED will blink

regularly. A successful

“511/E” test will confirm that the link is in place, and that the
Model 1065RC’s built-in “511” generator and detector are
working properly.

Summary of Contents for 1065RC

Page 1: ...Industrial Synchronous Asynchronous Short Range Modem Rack Mount Card SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1065RC A Doc 058051UA Revised 08 11 99 An IS...

Page 2: ...wever there is no guarantee that interfer ence will not occur in a particular installation If the Model 1065RC does cause interference to radio or television reception which can be determined by turni...

Page 3: ...o point or multipoint Internal external or received loopback clocking Built in transformer isolation high speed surge protection Mono color LED indicators 2000VAC transformer isolation Mounts in Patto...

Page 4: ...S2 and S3 which are mounted on the PC board Figure 1 These configura tion switches allow you to select data rates clocking methods V 52 V 54 tests word lengths extended signaling rates async or sync...

Page 5: ...ic tests and 2 and 4 wire opera tion The default settings for S2 are shown in Figure 6 below Switches S2 1 and S2 2 Word Length Switches S2 1 and S2 2 are set in combination to determine the word leng...

Page 6: ...the antistream control local loopback enable remote loopback enable and receive input impedance levels for the Model 1065RC The default settings are shown in the S3 sum mary table S3 1 Input Impedance...

Page 7: ...ack test can be initiated by raising pin 21 on the RS 232 interface S3 6 Setting On RS 232 initiation enabled Off RS 232 initiation disabled S3 7 and S3 8 Antistream Control Switches S3 7 and S3 8 are...

Page 8: ...odel 1000RMC12545 DB 25 RJ 45 rear cards These straps determine various grounding characteristics for the RS 232 and twisted pair lines Figure 10 shows the orientation of the rear interface card strap...

Page 9: ...n power supply Measuring only 3 5 high the Model 1001R14P is designed to occupy only 2U in a 19 rack Sturdy front handles allow the Model 1001R14P to be extracted and transported conveniently 4 1 1 TH...

Page 10: ...1 Slide the rear card into the back of the chassis along the metal rails provided 2 Secure the rear card using the metal screws provided 3 Slide the card into the front of the chassis It should meet...

Page 11: ...4 Red Yellow 2 RCV RCV 5 Black Green 3 XMT GND 6 White Blue 1 GND RJ 45 4 Wire SIGNAL PIN COLOR COLOR PIN SIGNAL GND 2 Orange Brown 7 GND RCV 3 Black Green 5 XMT XMT 4 Red Yellow 6 RCV XMT 5 Green Bl...

Page 12: ...lowing Figure 15 is a description of each LED s function 5 1 1 The TD and RD Indicators The TD and RD indicators blink green with data activity Off indi cates a low RS 232 logic level green indicates...

Page 13: ...ate the condition of the modems and the communica tion link Both sets of tests can be activated physically from the front panel The V 54 test can also be activated from the RS 232 interface Note V 54...

Page 14: ...king properly 5 If the remote BER test indicates that errors are present and the local analog loopback BER tests showed that both Model 1065RCs were functioning properly this suggests a problem with t...

Page 15: ...1 h x 5 4 l APPENDIX B PATTON ELECTRONICS MODEL 1065RC CABLE RECOMMENDATIONS All Patton Electronics Company Short Range Modems are tested to the distances published in our Catalogs and Specification...

Page 16: ...sted below Patton Model Description 1000RPEM 120 240V Rear Power Entry Module 1000RPSM 1 120 240V Front Power Supply Module 1000RPEM DC DC Rear Power Entry Module 1000RPSM 48A 48V Front Power Supply M...

Reviews: