5.0  OPERATION

Once you have configured each Model 1004ABRC and connected

the cables, you are ready to operate the units. Section 5.0 describes
the LED status monitors and the power-up procedure.

5.1  LED STATUS MONITORS

The Model 1004ABRC features front panel LEDs that indicate the

condition of the modem and communication link. Figure 6 (below)
shows the positions of the LEDs.

• 

The green “PWR” LED glows when power is applied to
the modem through its mid-plane chassis connection.

• 

The green “TD” and “RD” LEDs show positive state data
activity. The red “TD” and “RD” LEDs show negative state
data activity. A solid red light indicates an idle state.

• 

The green “CD” LED lights when the receive carrier is
detected; the red LED lights when the receive carrier is
absent.

5.2  POWER-UP

There is no power switch on the Model 1004ABRC: Power is auto-

matically applied to the 1004ABRC when its card-edge connector
touches the chassis’ mid-plane socket, or when the chassis’ power is
turned on.

APPENDIX A

PATTON ELECTRONICS MODEL 1004ABRC

SPECIFICATIONS

Transmission Format:

Asynchronous

Data Rate:

0 to 115.2 Kbps

Surge Protection:

Silicon Avalanche Diodes

Control Signals:

DSR turns “ON” immediately after the termi-
nal raises DTR; DCD turns “ON” after re-
cognizing the receive signal from the line;
CTS turns on after the terminal raises RTS

Transmission Line:

2-wire or 4-wire, unconditioned twisted pair

Transmit Mode:

Full or half duplex

Transmit Level:

2V ± 10% differential output voltage 

Carrier:

Controlled by data transitions 

RTS/CTS Delay:

8 msec or zero

Echo Mode:

Echo and No Echo, supported in both 
2-wire and 4-wire modes

Receiver Impedance:

Low (120 ohms), High (100k Ohms)

Line Connection:

RJ-11 or RJ-45 jack

Surge Protection:

Silicon Avalanche Diodes on twisted pair 
interface from each line to frame ground

Power Supply:

Rack-mount power supply is switchable 
between 120V and 240V AC; rack chassis 
supplies 10V AC to the Model 1004ABRC, 
typical consumption is 700 mW per card

Fuse:

400mA for 120V applications; 200mA for 
240V applications

Temperature Range:

0-50°C (32-122°F)

Altitude:

0-15,000 feet

Humidity:

Up to 95% non-condensing

Dimensions:

0.95”w x 3.1”h x 5.4”l

Figure 6. The Model 1004ARC front panel, showing LED positions

Model 1004RC

Power

TD

RD

CD

TD

RD

CD

Unit

A

Unit

B

NOTE:

The 1004ABRC is a “hot swappable” card—it will not be

damaged by plugging it in or removing it while the rack is pow-
ered up.

Summary of Contents for 1004ABRC

Page 1: ...igh Speed Multipoint Short Range Modem Rack Mount Card SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M1004ABRC A Doc 047053UA Revised 09 02 99 C E R T I F I E D A...

Page 2: ...arising from the use of or inability to use this product Patton Electronics specifically disclaims all other warranties expressed or implied and the installation or use of this product shall be deeme...

Page 3: ...ports up to 50 multipoint drops in a polling environment Passes transmit receive data Variable high low impedance settings Operates with or without local echo Features 6 easy to read LEDs Silicon Aval...

Page 4: ...a descriptions of each switch s function SWITCH SET S1 DIP switch S1 is used to configure receive impedance RTS CTS delay carrier control operation and echo enable disable The summary table below show...

Page 5: ...o determine whether the Model 1004ABRC is in 2 wire or 4 wire operating mode Note 2 wire mode is half duplex only S1 2 S1 3 Setting On On 2 wire mode Off Off 4 wire mode 3 1 2 SWITCH SETTINGS MODEM B...

Page 6: ...ations The summary table below shows the factory default settings for switch S4 Following the summary table is a detailed description of each individual switch S4 1 and S4 2 Transmit Off Impedance Swi...

Page 7: ...osed position the strap links RJ 11 pins 1 and 6 RJ 45 pins 2 and 7 to frame ground These pins can be used as connections for the twisted pair cable shield In the open disconnected position pins 1 and...

Page 8: ...K CHASSIS The Model 1000R16 Rack Chassis Figure 5 has sixteen short range modem card slots plus its own power supply Measuring only 3 5 high the Model 1000R16 is designed to occupy only 2U in a 19 rac...

Page 9: ...pment Therefore it wants to connect to a DTE Data Termination Equipment If your RS 232 output device is a DTE you may need to use a special cable such as a DB 25 to modular cable If your RS 232 output...

Page 10: ...SIGNAL PIN PIN SIGNAL XMT 3 3 XMT XMT 4 4 XMT RJ 45 Cable 2 Wire SIGNAL PIN PIN SIGNAL XMT 4 4 XMT XMT 5 5 XMT Connection to ground is optional 4 4 2 MULTIPOINT TWISTED PAIR CONNECTION The Model 1004...

Page 11: ...ps Surge Protection Silicon Avalanche Diodes Control Signals DSR turns ON immediately after the termi nal raises DTR DCD turns ON after re cognizing the receive signal from the line CTS turns on after...

Page 12: ...ticular site Use the above data rate distance table as a general guideline only APPENDIX C PATTON ELECTRONICS MODEL 1004ABRC FACTORY REPLACEMENT PARTS The Patton Model 1004ABRC rack system features in...

Page 13: ...Wire RJ 45 Contact Number Circuit Description 1 N A Not Used 2 125 DSR 3 109 Received Line Signal Indicator CD 4 108 2 DTE Ready DTR 5 102 Signal Common 6 104 Received Data 7 103 Transmitted Data 8 10...

Reviews: