background image

4.0  INSTALLATION

This section describes the functions of the Model 1001R14P rack

chassis, tells how to install front and rear Model 1001CC cards into the
chassis and provides diagrams for wiring up the interface connections
correctly.

4.1  THE MODEL 1001R14P RACK CHASSIS

The Model 1001R14P Rack Chassis (Figure 3, below) has sixteen

short range modem card slots, plus its own power supply.  Measuring
only 3.5” high, the Model 1001R14P is designed to occupy only 2U in a
19” rack.  Sturdy front handles allow the Model 1001R14P to be
extracted and transported conveniently.

4.1.1  THE RACK POWER SUPPLY

The power supply included in the Model 1001R14P rack uses the

same mid-plane architecture as the modem cards.  The front card of
the power supply slides in from the front, and the rear card slides in
from the rear.  They plug into one another in the middle of the rack.
The front card is then secured by thumb screws and the rear card by
conventional metal screws.

Powering the 1001R14P Rack

The power supplies that come with the 1001R14P rack system are

equipped with a power entry connector on the rear card.  The power
supplies are 

Hot-Swappable.  Therefore, you are not required to

remove power before removing or re-inserting cards into the rack.

6

SGND & FRGND (JB5)

In the connected (closed) position, this strap links signal ground

and frame ground.  In the open (disconnected) position, pin 1 is “lifted”
from frame ground. 

JB5

Position 1&2  =  SGND and FRGND Connected 

(Default)

Position 2&3  =  SGND and FRGND Not Connected

DTE as DSR or RI (JB6 & JB7)

Because this rear card is designed to function in more applications

than the Model 1001CC, this jumper must be installed only in one
position.  Place the jumper across pins 1&2 so that the terminal (DTE)
sees DSR as high when the DTE raises DTR.  The other positions,
across pins 2&3, are for Ring Indicate as defined by EIA/TIA-561.  The
RI function is irrelevant (and on the Model 1001CC is also
disconnected) and can cause improper operation if the jumper is
installed incorrectly.

JB6 & JB7

Position 1&2  =  DSR 

(default)

Position 2&3  =  N/A

5

Figure 3. Model 1001R14P Rack Chassis with power supply 

Summary of Contents for 1001CC

Page 1: ...MANUAL MODEL 1001CC RS 232 Rack Mount Controller Card SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 www patton com Part 07M1001CC B Doc 022030UB Revised 02 21 00 An ISO 9001 Certified Comp...

Page 2: ...of FCC rules which are designed to provide reasonable protection from such interference in a commercial installation However there is no guarantee that interference will not occur in a particular inst...

Page 3: ...nt Controller Card fits in Patton s NetLink Rack Chassis and Cluster Boxes and allows the Patton NetLink Rack Cards to be controlled from an asynchronous RS 232 terminal Taking up one card slot the Mo...

Page 4: ...s Powering the 1001R14P Rack The power supplies that come with the 1001R14P rack system are equipped with a power entry connector on the rear card The power supplies are Hot Swappable Therefore you ar...

Page 5: ...HASSIS The Model 1001CC is comprised of a front card and a rear card The two cards meet inside the rack chassis and plug into each other via mating 50 pin card edge connectors Follow the steps below t...

Page 6: ...C 2 Using a straight through modular cable connect Port B1 of the local Model 1001CC to port A1 to the RS 232 port of a Patton asynchronous short range modem card ex the Model 1000RC 3 Following the i...

Page 7: ...ctivity The red TD and RD LEDs show negative state data activity A solid red light indicates an idle state 5 2 POWER UP There is no power switch on the Model 1001CC Power is automatically applied to t...

Page 8: ...d 0805AUS Australia New Zealand Power Cord 0805DEN Denmark Power Cord 0805FR France Belgium Power Cord 0805IN India Power Cord 0805IS Israel Power Cord 0805JAP Japan Power Cord 0805SW Switzerland Powe...

Reviews: