background image

-

 

Check all parts for signs of wear or damage. All scratched, cracked or pitted parts must 
be immediately replaced to avoid personal injury. 

-

 

Carry out a performance test to make sure the welding helmet operates properly. 

-

 

Always choose a correct shade to each welding application according to welding process, 
welding machine and welding current in use. 

 

Shade adjustment 

Shade can be adjusted between 9-13 by simply turning the shade adjusting knob outside the 
helmet.  You can utilize the 

Shade chart

  below when choosing the correct shade for  each 

welding application. 
 
 
 
 
 
 
 
 
 
 

 

Shade chart 

 

Delay adjustment 

Delay is time after which the filter returns from dark state back to clear state, in other words 
time which the filter stays dark after the arc goes  out.  Delay can be adjusted with the 
”DELAY” knob between fast and slow. 

-

 

Delay time control knob in ”MIN” position: time varies between 0,1–0,25 seconds; suita-
ble for spot welding, short welding operations and seam welding. 

-

 

Delay time control knob in ”MAX” position: time varies between 0,85–1,0 seconds; suita-
ble for high current welding and to prevent eye fatigue from the arc. 

-

 

Delay time control knob in middle position: suitable for most indoor and outdoor welding 
operations. 

 

Sensitivity adjustment 

Sensitivity can be adjusted with the ”SENSITIVITY” knob according to welding process and 
ambient light. Default sensitivity is at the lowest level. 

-

 

Sensitivity control knob in ”LO”  position:  suitable for high  current welding, and when 
welding in bright light environment or when welding in environment with other interfering 
light sources. 

-

 

Sensitivity control knob in ”HI” position: suitable for low current welding, and when weld-
ing in low light environment, especially for low current argon arc welding. 

-

 

Sensitivity control knob in middle position: suitable for most indoor and outdoor welding 
operations. 

 

Welding/Grinding 

Set the shade adjusting knob outside the helmet to ”Grind” position during grinding. 
 

 

 WELDING 

 PROCESS 

 

Electrode welding 

 

MAG 

 

TIG 

 

MIG, heavy metals 

 

MIG, light alloys 

 

Plasma arc cutting 

 

Plasma arc welding 

 

ARC CURRENT IN AMPERES 

 

14 

Summary of Contents for HM002

Page 1: ...358 0 20 1323 388 tuotepalaute ikh fi www ikh fi HM002 Lue k ytt ohjeet huolellisesti ennen laitteen k ytt ja noudata kaikkia annettuja ohjeita S ilyt ohjeet my hemp tarvetta varten L s noggrant igeno...

Page 2: ...smaski ei sovellu laserhitsaukseen tai asetyleenikaasuhitsaukseen Hitsausmaski on suojattava kuumuudelta ja kosteudelta l avaa tai irrota automaattisesti tummuvaa ADF hitsauslasia maskista Varmista en...

Page 3: ...anturit 2 kpl Toiminnot Hitsaus Hionta Alhaisen paristotehon merkkivalo kyll Testauspainike kyll K ytt l mp tila 5 C 55 C Varastointil mp tila 20 C 70 C Paino 480 g OSAT 1 Maskin runko 2 P panta 3 P p...

Page 4: ...sti maskin ulkopuolella sijaitsevaa tummuusasteen s t nuppia k nt m ll Voit k yt t apuna alla olevaa Tummuusastetaulukkoa valitessasi kulloiseenkin hitsauskohteeseen sopivaa tummuusastetta Tummuusaste...

Page 5: ...tisesti kirkkaaseen tilaan P pannan s t P pannan kireytt voidaan s t k ytt j lle sopivaksi p pannan takana sijaitsevaa nuppia k nt m ll Oikealle k nnett ess p panta kiristyy ja vasemmalle k nnett es s...

Page 6: ...l k yt alle 5 C l mp tilas sa Nosta herkkyys oikealle tasolle Huono n ky vyys Suojalasi on likainen Muovista suojakalvoa ei ole poistet tu ADF hitsauslasi on likainen Ymp rist n valaistus ei ole riitt...

Page 7: ...te utf ras av barn utan uppsikt Denna svetshj lm l mpar sig inte f r lasersvetsning eller acetylengassvetsning Svetshj lmen ska skyddas mot hetta och fukt ppna eller avl gsna inte det automatiskt avbl...

Page 8: ...ner Svetsning Slipning Signalljus f r l g batteriniv ja Testknapp ja Drifttemperatur 5 C 55 C F rvaringstemperatur 20 C 70 C Vikt 480 g DELAR 1 Hj lmstomme 2 Huvudbindsle 3 Justeringsknappar f r huvud...

Page 9: ...sidan av hj lmen Du kan anv nda M rkhetsgradstabellen nedan som st d n r du v ljer den l mpligaste graden f r varje svetsningsarbete M rkhetsgradstabell Justering av f rdr jningen Med f rdr jningen me...

Page 10: ...et bl ndas av och d refter automatiskt terst lls till ljust l ge Justering av huvudbindslet Huvudbindslet kan justeras till l mplig passform genom att vrida p ratten p baksidan av huvudbindslet Vrid t...

Page 11: ...nd inte i temperaturer under 5 C H j k nsligheten till r tt niv D lig sikt Skyddsglaset r smutsigt Skyddsfilmen av plast har inte avl gsnats ADF svetsfiltret r smutsigt Otillr ckligt belyst omgivning...

Page 12: ...lene welding The welding helmet must be protected from heat and moisture Do not open or remove the auto darkening filter from the helmet Before operation make sure that the Welding Grinding selection...

Page 13: ...6 Cover glass 7 Solar panel 8 Cartridge 9 Cover frame 10 UV IR filter 1 Test button 2 Delay time control knob 3 Sensitivity control knob 4 LCD 5 Batteries 6 Low battery indicator 7 Solar cell 8 UV IR...

Page 14: ...tions and seam welding Delay time control knob in MAX position time varies between 0 85 1 0 seconds suita ble for high current welding and to prevent eye fatigue from the arc Delay time control knob i...

Page 15: ...ents solvents or gasoline to clean the welding helmet or any of its parts Replace the inner or outer cover glass immediately if scratched cracked pitted or other wise damaged TROUBLESHOOTING Problem C...

Page 16: ......

Page 17: ......

Reviews: