FC-3 PRODUCT MANUAL
GFCI PROTECTION AND ON-BOARD
DUPLIX OUTLET:
The standard AC voltage outlet GFCI (Ground Fault Circuit Interrupter) promotes operator
safety in wet applications. GFCI devices trips when a fault to electrical ground is sensed. It
is recommended to check the GFCI protection prior to operation. To check, push the "TEST"
button located on the GFCI duplex outlet. If operating correctly, the "RESET" button on the
GFCI will pop-out. A tripped GFCI will be indicated by a pop-out "RESET" button. Press the
"RESET" button to return the GFCI to normal operation. The machine can only be "RESET"
when it is connected to a wall outlet providing standard voltage. The duplex AC outlet allows
the inter-connection of other air movers or AC powered devices. The sum total ameprage of all
devices (excluding the first fan) plugged into the receptacle must not exceed 8.7 amps.
TROUBLESHOOTING:
PROBLEM
CAUSE
SOLUTION
1. Plug unit in. Check circuit breaker.
1. No power to unit.
2. Place in "ON" position.
Unit will not turn 2. Switch not on.
3. Replace switch.
on.
3. Switch is faulty.
4. Perform continuity check, using
4. Faulty/broken cord or motor wire
volt/amp meter. Repair/replace
broken wire.
1. Unit has been severely dislodged
Unit runs but fan causing blower wheel to rub against
1. Remove motor and replace
makes loud
housing.
damaged motor mounts.
scraping noise. 2. Blower wheel has been severely
2. Replace blower wheel.
deformed.
1. Severe dislodging has bent motor
1. Remove and replace motor.
Unit runs but
shaft causing unit to be out of balance.
vibrates
2. Blower wheel is damaged.
2. Replace blower wheel
excessively.
3. Dirt build up on one side of blower
3. Clean blower wheel.
wheel.
Unit runs but
1. Motor bearings are failing or motor
1. Remove and replace motor.
blower wheel does has developed an internal electrical fault.
not turn.
2. Intake grill and/or exhaust grill
2. Remove obstruction.
obstructed.
Page 5