OPERATION:

Blower comes completely assembled and ready to operate. Inspect all components for any 

damage that may occur during shipping. Plug blower into a standard grounded outlet with the 

correct voltage and amperage. If you are unsure about the outlet, contact your supervisor. Turn 

on the switch and check that the unit operates properly before operation. 

GROUNDING INSTRUCTIONS:

This machine must be grounded. If it should malfunction or break down, grounding provides a 

path of least resistance for electric current to reduce the risk of electric shock. This machine is 

equipped with a cord having an equipment-grounding conductor and grounding plug. The plug 

must be inserted into an appropriate outlet that is properly installed and grounded in 

accordance with all local codes and ordinances. 

Improper connection of the equipment-grounding conductor can result in a risk of electric 

shock. Check with a qualified electrician or service person if you are in doubt as to whether the 

outlet is properly grounded. Do not modify the plug provided with the machine if it will not fit the 

outlet; have a proper outlet installed by a qualified electrician. This machine is designed to 

operate on a standard 15 AMP, 115 Volt, 60 Hz, AC Circuit. Voltage below 105 Volt AC or 

above 125 Volts AC could cause serious damage to the motor. 

EXTENSION CORDS:

Use only three-wire 12/3 or larger gauge approved extension cords that have three-prong 

grounding type plugs and three-pole receptacles that accept the machine’s plug. Replace or 

repair any damaged cords or plugs.

MAINTENANCE:

Inspect the electrical cord and wiring for damage discoloration.

 

Inspect for loose fasterners.

Clean screens on the side and front of the unit.

Turn on unit and listen for abnormal sounds.

Keep polythelene chassis clean.

Use compressed air or a vacuum to remove lint and other debris from the motor, screen and 

blower wheel. Do not use a pressure washer to clean the unit. 

Summary of Contents for FA-12

Page 1: ...FA 12 12 AXIAL FAN PRODUCT MANUAL RENTQUIP 1 800 818 1199 WWW PATRONPRODUCTS COM IMPORTANT READ AND UNDERSTAND THIS MANUAL BEFORE USE KEEP THIS MANUAL FOR FUTURE REFERENCE ...

Page 2: ... and moving parts DO NOT stand directly in front of and or face the blower outlet Personal injury may result from debris being thrown from the blower fan at high velocity DO NOT use electrical transformer to modify or alter the motor s frequenzy Hz DO NOT place machine near flammable materials and vapors Do not use or store this machine with or near fuels grain dust solvents thinners or other flam...

Page 3: ...g checked regularly DO a visual inspection of the blower and check for damged worn loose and or broken parts Ensure all safety devices are operable and information decals are readable Check to see the blower and all related accessories are in good mechanical condition before use DO verify that the blower uses appropriate electrical cord and NEMA plug For maximum pro tection against electrical shoc...

Page 4: ...r can result in a risk of electric shock Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded Do not modify the plug provided with the machine if it will not fit the outlet have a proper outlet installed by a qualified electrician This machine is designed to operate on a standard 15 AMP 115 Volt 60 Hz AC Circuit Voltage below 105 Vo...

Page 5: ...verely dislodged causing fan to rub against housing vane motor mount 2 Vane motor mount has been severely deformed 1 Remove wire grill and reinstall or replace fan blade 2 Reinstall or replace Vane motor mount Unit runs but vibrates excessively 1 Dislodging has bent motor position causing unit to be out of balance 2 Motor is damaged 1 Reinstall motor with new mounts 2 Replace Motor Unit runs but m...

Page 6: ...ART NUMBER DESCRIPTION QTY 2 F1018 WIRE GRILLS 2 9 F1025 CAPACITOR 1 3 F1019 FAN BLADE 1 10 F1026 NUT HEX 1 4 F1020 VANE MOTOR MOUNT 1 11 F1027 GASKET 1 5 F1021 AC MOTOR 1 12 F1028 SWITCH PLATE 1 6 F1022 PLASTIC CASING 1 13 F1004 STRAIN RELIEF 1 7 F1023 RIVET 4 14 F1030 SWITCH ASSEMBLY 1 8 F1024 RUBBER FOOT 4 15 F1031 POWER CORD 1 ...

Page 7: ...S AND DISTRIBUTORS AND IS IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED During the warranty period Patron Products will at its sole option repair or replace any defective parts or products returned freight prepaid to Patron Products or such other location as Patron Products may designate Returned products must be packaged carefully and Patron Products shall not be responsible for damage in tr...

Page 8: ...PATRON PRODUCTS A DIVISION OF RENTQUIP 1 800 818 1199 www patronproducts com ...

Reviews: