60E PRODUCT MANUAL
RENTQUIP USA INC. | 1-800-818-1199 | WWW.PATRONPRODUCTS.COM
OPERATION
REVIEW AND UNDERSTAND ALL WARNINGS IN THIS MANUAL. THEY ARE ESSENTIAL FOR SAFE USE
OF THE HEATER.
FOLLOW ALL LOCAL CODES
TO START HEATING:
1. Place the heater on a stable and level surface. Make sure that no explosive or combustible fumes or dust
are present.
MINIMUM CLEARANCES FROM COMBUSTABLE MATERIALS
OUTLET = 6 feet
SIDES = 1 foot
TOP = 2 feet
REAR = 2 feet
FLOOR = COMBUSTABLE
2. Connect power cord of heater into 480 V / 60 Hz three phase power source. THE POWER SOURCE MUST
BE EQUIPPED WITH A CIRCUIT BREAKER! See paragraph “Technical specifications” in this manual for
correct amperage rating. NOTE: Check your heater to make sure it is wired for either one or three phase
use.
3. Set the room thermostat to a temperature above the ambient room temperature by turning the knob. Note!
The heater will start heating only if the thermostat “calls for heat” meaning that it is set to higher than pre-
vailing ambient temperature
4. Select the power range by means of the switches marked S1, S2 and S3.
S1 “ON” = Partial output 24 kW (84,000 BU/h)
S1 & S2“ON” = Partial output 48 kW (164,000 BU/h)
S1 & S2 & S3 “ON” = Full output 60 kW (205,000 BU/h)
THE HEATER WILL NOW OPERATE AUTOMATICALLY, CONTROLLED BY THE THERMOSTATS.
TO STOP HEATING
1. Turn the main switch into position “0” standby
2. Let the fan run until it stops automatically - do not disconnect heater from power source!
3. Disconnect the power supply plug
NOTE!
THE HEATER IS EQUIPPED WITH AN OVERHEAT LIMIT SWITCH WHICH MAY CAUSE THE HEATER TO
STOP. CHECK AND REMOVE THE CAUSE FOR OVERHEATING BEFORE RESTARTING.