2
Installation
1
Connect the Fence ground terminal to a
separate ground system that is at least 33’
(10 m) away from other ground systems.
2
Connect the Fence output terminal to the
fence.
Indoors/Dry locations with mains/line
connector
Operation
1
Plug the unit into the mains/line power
supply.
2
Turn on the mains/line power supply
switch.
The pulse indicator light flashes each time
the unit pulses.
Building an electric fence
Note:
This product has been designed for use
with electric animal fences.
For information about building an electric fence,
refer to the Patriot website
www.patriotglobal.com.
Installing and testing a
ground system
Select a suitable site for the ground system.
Sites need to be at least 33’ (10 m) from other
ground systems (e.g. telephone, mains/line
power or the ground system of another unit).
Drive 6’ (2 m) ground rods into the soil. The
table below specifies the minimum number of
6’ (2 m) ground rods recommended for a
ground system:
Model
Ground rods
Patriot PMX50
1
Patriot PMX120
2
Patriot PMX200
3
Patriot PMX350
4
Patriot PMX450
5
Patriot PMX600
6
Safety considerations
Warning!
-
USA and Canada - To reduce the risk of
electric shock, the unit’s power adaptor
may have a polarized plug (one blade is
wider than the other). This plug will fit in a
polarized outlet one way. If the plug does
not fit fully in the outlet, reverse the plug.
If it still does not fit, contact a qualified
electrician to install the proper outlet. Do
not change the plug in any way.
-
Switch the unit off before installation or
performing any work on the fence.
-
Read all the safety considerations
carefully.
Summary of Contents for PMX120
Page 43: ...43 Patriot PMX50 PMX120 PMX200 PMX350 PMX450 PMX600 1 2 1 2 PATRIOT www patriotglobal com...
Page 45: ...45 2 5m 10m 10cm X 20cm 2 5cm...
Page 46: ...46 2 5 m 15cm PATRIOT www patriotglobal com 1000V 3 m 1000V 33 000V 4 m 33 000V 8 m...
Page 47: ...47 PATRIOT www patriotglobal com PATRIOT www patriotglobal com TRU TEST...
Page 48: ...48 Notes...