CAUTION
:
The lamp
fi
xture is designed to be mounted so that the
mo
ti
on detector controls face towards the ground. If the lamp
fi
xture
is mounted in any other posi
ti
on, it may be possible for water to enter
the unit and cause damage to the unit and cause possible electric shock.
Make sure the controls are facing towards the ground!
IMPORTANT
:
A
ft
er moun
ti
ng the
fi
xture, it will be necessary to apply silicone sealant
caulking compound completely around the perimeter of the
fi
xture
where the back of the cover plate meets the moun
ti
ng surface. Silicone
caulking prevents water from entering the junc
ti
on box.
Your installa
ti
on is now complete. Turn on power at the circuit breaker
and flip the wall switch to the ON posi
ti
on. The wall switch must
remain in the ON posi
ti
on for the mo
ti
on detector to operate properly.
MANUAL OVERRIDE
:
You can also turn the light on manually from the wall switch by
fl
ipping
the wall switch o
ff
for 1 to 3 seconds and then back on. The light will
stay on un
ti
l you
fl
ip the switch o
ff
and on again. If you leave the light
on all night, the light will automa
ti
cally turn o
ff
at dawn and return to
SECURITY mode. Flip the light switch o
ff
and on to toggle twice in 3
seconds, it will change between AUTO and MANUAL MODE with the
light staying on for 5 hours. The MANUAL OVERRIDE feature only works
at night or when in TEST mode.
Make sure power is turned on at circuit breaker and wall
switch is in the ON posi
ti
on. Wall switch must remain in
the ON posi
ti
on for the mo
ti
on detector to work properly.
There are three control
knobs on the bo
tt
om
Of the light
fi
xture
to control the
mo
ti
on detector.
The control knobs are:
1. MODE SELECT: Security Mode/Dusk to Dawn Mode
2. TIME/TEST
3. SENSITIVITY
1.
MODE SELECT
:
SECURITY/DUSK to DAWN
SECURITY:
Your ligh
ti
ng
fi
xture is energy-saving when
used in SECURITY mode. In this mode the light will come on
at night only when mo
ti
on is detected. The light will stay on
as long as mo
ti
on con
ti
nues and stay on for a brief ON
ti
me
a
ft
er all mo
ti
on has stopped. The ON
ti
me is set with the
TIME/TEST knob discussed below. To put the
fi
xture into the
SECURITY mode, turn the MODE SELECT knob fully
counterclockwise so that the small pointer is aimed toward
the SECURITY se
tti
ng
.
DUSK to DAWN:
To put the lamp
fi
xture into the DUSK to
DAWN mode, turn the MODE SELECT knob fully clockwise
so that the small pointer is aimed towards the DUSK to
DAWN se
tti
ng. In this mode the lights automa
ti
cally come
on at dusk and turn o
ff
at dawn. Mo
ti
on has no e
ff
ect.
Page
5
Page
6
OPERATING INSTRUCTIONS
Junc
ti
on box wire may be red and/or have a copper conductor. The
White junc
ti
on box wire may be square and/or have a silver conductor.
4
.
MOUNT FIXTURE.
Make sure wire connec
ti
ons
are secure. Carefully posi
ti
on wires and wire nuts
into the junc
ti
on box. Posi
ti
on the crossbar (C)
so that the
fi
xture moun
ti
ng studs are level.
Carefully posi
ti
on the light
fi
xture (A) over the
junc
ti
on box so that the moun
ti
ng studs protrude
through the front cover on the
fi
xture. Thread
the decora
ti
ve nuts back onto the studs to secure
the light
fi
xture to the junc
ti
on box. Tighten the
decora
ti
ve nuts so that the light
fi
xture is secure
and flush with the moun
ti
ng surface. DO NOT
over
ti
ghten.
Silicone
Caulking Tube
DUSK/DAWN SECURITY TIME
TEST
SENSITIVITY