14
Symbols
Indicates that the air inlets are blocked. Remove the blockage and provide adequate ventilation.
Flashes when the power station is overheated or undercooled. The intelligent protection program is automati-
cally triggered and the Powerstation stops operating. Wait until the power station is acclimatized.
Flashes when there is a charging error. Please check the connection and power supply.
Flashes when the output values are abnormal. Please check the connected devices and connections.
Flashes when the output values are abnormal. Please check the connected devices and the connections.
Press and hold the USB button for 2 seconds to enter the whisper mode.
Double press the AC button to switch to DC mode.
06 Ventilation slots
► Cooling starts automatically as soon as the power station generates corresponding heat.
► Do not block the ventilation slots under any circumstances.
► Do not insert any objects into the ventilation slots.
► Ensure a distance of min. 30 cm to walls and objects.
07 PV DC input
► You can charge the power station with a solar panel.
► To do this, connect the appropriate cable to the power station and the solar panel (see section „Charging with the
solar panel“).
Caution:
► The input power can be up to 1000W, maximum voltage 120V.
► If the PV DC input port is loaded with more than 120V, the power station will be damaged.
08 AC switch Quick Charge Function
► Turn the switch to the required setting.
Caution:
► When using the fast charge function, make sure the output voltage is 200-240V.
► The charging power is up to 1800 W.
09 AC input
► You can charge the charging station using the AC input.
► Make sure that the mains voltage and frequency of the power station matches the mains voltage and frequency of
the AC input.
10 Overload protection switch
► If the voltage is unstable, e.g. due to lightning and other reasons, and/or if the input voltage at the AC input is too
high, the safety circuit is triggered. This will protect the power plant.
► If the safety circuit has been triggered, proceed as follows:
1. Turn off the power station and disconnect all cables from the terminals.
2. Check the power supply and all equipment to be connected.
3. If you do not find any anomalies, you can restart the power station.
EN I PATONA Platinum Powerstation Autarc 5000
Summary of Contents for Platinum Powerstation Autarc 5000
Page 107: ...106 5000 1000 120 5 120 1 AC PV 2 AC PV SR I PATONA Platinum Powerstation Autarc 5000...
Page 108: ...107 5000 5 6 7 1 90 12 8 24 10 AC PV SR I PATONA Platinum Powerstation Autarc 5000...
Page 110: ...109 2200 2200 2200 10 45 50 3 SR I PATONA Platinum Powerstation Autarc 5000...
Page 111: ...110 30 PATONA Platinum Powerstation Autarc 5000 SR I PATONA Platinum Powerstation Autarc 5000...