background image

- 5 -

                                     PATON VDI SERIES ECO  DC MMA 

The basic advantages of the PATON™ welding unit are the following: 

1.

 

The  welding  unit  is 

protected  against  long-time  fluctuations

  of  power  supply  voltage  and 

provides  arc  stabilization  when  the  input  voltage  of  the  unit  changes  in  the  range  of  170  V 
through 260 V.  

2.

 

The welding unit is rated for operation with the standard power supply system. Due to the higher 
efficiency coefficient of the unit, 

the power consumed by the unit is reduced by 50 percent

 as 

compared with other similar welding units. 

3.

 

The rotation frequency of the ventilator motor can be 

automatically varied depending on the 

temperature  inside  the  unit

.  This  feature  allows  the  service  life  of  the  ventilator  motor  to  be 

increased and, additionally, dust content inside of the unit to be reduced.  

4.

 

The  welding  unit  is  easy  operated  due  to  the  optimal  operating  load  factor  in  operation 

at  the 

rated current

. In these conditions, it is possible to perform welding by using 4 mm electrodes at 

the rated current. 

5.

 

The enhanced reliability of the welding unit in operation in dusty environment. 

6.

 

All  the  printed-circuit  boards  with  electronic  elements  are 

impregnated  with  two  layers  of 

high-quality  varnish

  in  order  to  provide  the  high  reliability  of  the  welding  unit  during  its 

service life. 

7.

 

The possibility to smoothly adjust welding parameters. 

8.

 

Enhanced arc stability. 

 

1.1.

 

 TECHNICAL CHARACTERISTICS 

PARAMETERS

 

VDI – 160E

 

VDI – 200E

 

VDI – 250E 

Rated voltage 50/60 Hz, V 

230 

230 

230 

Rated power supply current, A 

20 

25 

32 

Rated welding current, A 

160 

200 

250 

Maximum operating current, A 

190 

240 

300 

Operating load factor, % 

40% at 160А 

100% at 101A 

40% at 200А 

100% at 126A 

40% at 250А 

100% at 158А 

Power supply voltage range, V 

170 – 260 

170 – 260 

170 – 260 

Welding current control range, A 

20 – 160 

25 – 200 

32 – 250 

Function “Hot-Start”  

Automatic 

Function “Arc-Force”  

Automatic 

Function “Anti-Stick” 

Automatic 

Open-circuit voltage, V 

to 80 

to 80 

to 80 

Welding arc starting voltage, V 

110 

110 

110 

Rated consumed power, kVA 

4,4 

5,5 

7,0 

Maximum consumed power, kVA 

5,5 

6,9 

8,8 

Efficiency coefficient, % 

90 

90 

90 

Cooling  

Forced 

Operating temperature range 

–25 … +45ºС 

–25 … +45ºС 

–25 … +45ºС 

Overall dimensions (length 

 width 

 height), 

mm 

245 х 100 х 

200 

270 х 100 х 200 

270 х 110 х 

200 

Weight, kg 

3,75 

3,95 

4,3 

Protection class* 

IP21 

IP21 

IP21 

*The  Eco  series  equipment  is  protected  against  ingress  of  foreign  particles  more  than  5.5  mm  in  size  and  against  water 
drops 
 

 

Summary of Contents for VDI-160E

Page 1: ...1 PATON VDI SERIES ECO DC MMA Operation Manual Inverter rectifiers PATON VDI 160E VDI 200E VDI 250E 4 Contents...

Page 2: ...OVERED ELECTRODE ARC WELDING PROCESS MMA 8 3 1 INCREASED CURRENT ARC STARTING HOT START 9 3 2 REDUCED WELDING VOLTAGE FUNCTION ARC FORCE 9 3 3 PROTECTION AGAINST ELECTRODE STICKING ANTI STICK 10 4 MAI...

Page 3: ...es production are in conformity with the product sample detailed in this report The applicant should hold the whole technical report at disposal of the competent all the right Applied EC Directives 20...

Page 4: ...r rectifiers PATON VDI 160E VDI 200E VDI 250E optimized for direct current manual arc welding MMA This ECO series of devices designed for demanding users who wants the most compact and functional devi...

Page 5: ...the printed circuit boards with electronic elements are impregnated with two layers of high quality varnish in order to provide the high reliability of the welding unit during its service life 7 The...

Page 6: ...status of indicator a constantly lit green machine is ready to work b blinks green when striking there is no mains voltage c constantly lit yellow overheating of the source d does not light up no pow...

Page 7: ...nit is protected against ingress of foreign particles more than 5 5 mm in size and the internal elements of the unit are protected against moisture so the unit is allowed for outdoor operation WARNING...

Page 8: ...e welding unit see Subsection 1 1 Technical characteristics Connect the welding unit to an electrical outlet that is made for three wire earthing plugs 3 MANUAL CONSUMABLE ELECTRODE ARC WELDING MODE M...

Page 9: ...at the increased current arc starting stage is 90 0 33 90 120 A 3 2 REDUCED VOLTAGE WELDING FUNCTION ARC FORCE The advantages ensured by the reduced voltage welding function are the following The enh...

Page 10: ...ctrical outlet of the power supply system Wait for about 5 minutes until static charges in the unit circuits are removed and then perform the maintenance operations After completion of works with the...

Page 11: ...rding to State Norm for 5 years The welding unit should be stored in a dry closed room at an ambient temperature not lower than 5 C In the room acid vapors and chemically active substances should not...

Page 12: ...ble 3 m in length 1 pcs 2 Shoulder carry belt 1 pcs 3 Brand corrugated box PATON 1 pcs 4 Welding cable with an electrode holder 3 m in length 1 pcs 5 Welding cable with an earthing terminal 3 m in len...

Page 13: ...is sufficient for arc staring Select the welding electrode with consideration for the welding current Random arc extinction during welding The arc voltage is too high for the electrode used Use anoth...

Page 14: ...non flammable radiation absorbing screens VAPOUR AND GASES MAY BE DANGEROUS The resulting smoke and harmful gases should be removed from the work area by means of specialized equipment do not cover t...

Page 15: ...ny maintenance work on the unit Removing the outside cover of the device while it is connected to the network and using the device with the lid removed is forbidden NOISE ASSOCIATED WITH WELDING CAN B...

Page 16: ...PATON VDI SERIES ECO DC MMA 16 12 ELECTRICAL SCHEMATIC DIAGRAM 230 V CURRENT BIS 0331 BVR 0331 BPK 0332...

Page 17: ...the accumulation of conductive dust inside coal dust metal chips etc In case of attempting to repair its nodes and or replacement of electronic components Once on six months clean internal parts and c...

Page 18: ...above recommendations may result in the imposition of fines in accordance with applicable regulations If you would like to return the unit for disposal please contact your nearest point of sale or co...

Page 19: ...e Date of reception of the welding unit for repair _____ __________ 20 ___ year _______________________ signature Faults detected ______________________________________________________________________...

Page 20: ...__________ Tel Technical support 48 889 226 032 Address of the service center 38500 Poland Sanok Zamenhofa 9 Street Date of reception of the welding unit for repair _____ __________ 20 ___ year ______...

Reviews: