background image

PATON

 

PRO-series

 

DC

 

MMA/TIG/MIG/MAG

      ‐ 

20

 ‐

 

6.2

 

SWITCHING

 

TO

 

THE

 

REQUIRED

 

WELDING

 

MODE

  

Pressing

 

on

 

button

 

7

 

switches

 

the

 

machine

 

to

 

the

 

next

 

welding

 

mode

 

end

around;

 

the

 

process

 

of

 

switching

 

is

 

very

 

fast.

 

6.3

 

RESET

 

OF

 

ALL

 

FUNCTIONS

 

SETTINGS

 

FOR

 

THE

 

CURRENT

 

WELDING

 

MODE

 

There

 

can

 

be

 

situations

 

when

 

the

 

user

 

becomes

 

confused

 

with

 

the

 

machine

 

settings.

 

In

 

order

 

to

 

reset

 

them

 

to

 

standard

 

factory

 

values,

 

just

 

hold

 

button

 

5

 

for

 

more

 

than

 

10

 

seconds.

 

As

 

it

 

was

 

mentioned

 

in

 

the

 

paragraph

 

above,

 

the

 

board

 

will

 

display

 

countdown

 

333...222...111,

 

and

 

once

 

it

 

shows

 

"000",

 

all

 

settings

 

of

 

the

 

current

 

welding

 

mode

 

will

 

be

 

reset

 

to

 

factory

 

values.

 

In

 

order

 

to

 

reset

 

all

 

machine

 

settings,

 

this

 

procedure

 

shall

 

be

 

performed

 

for

 

each

 

mode

 

individually.

 

It

 

is

 

designed

 

this

 

way

 

for

 

convenience,

 

so

 

that

 

the

 

user

 

does

 

not

 

reset

 

customized

 

settings

 

of

 

the

 

remaining

 

two

 

modes.

  

7. GENERAL

 

LIST

 

AND

 

SEQUENCE

 

OF

 

FUNCTIONS

MMA

 

welding

 

mode

 

0) [

1

]

 

 

main

 

displayed

 

parameter

 

CURRENT

 

=

 

90

 

A

 

(by

 

default)

a)

8...

 

160

 

A

 

(increment

 

1

 

A)

 

for

 

PRO

160

b)

10...

 

200

 

A

 

(increment

 

1

 

A)

 

for

 

PRO

200

c) 12...

 

250

 

A

 

(increment

 

1

 

A)

 

for

 

PRO

250

1) [H.St]

 

Hot

 

Start

 

power

 

=

 

40%

 

(by

 

default)

a) 0[OFF]...

 

100%

 

(increment

 

1%)

2) [t.HS]

 

Hot

 

Start

 

time

 

=

 

0.3

 

s

 

(by

 

default)

a) 0.1...

 

1.0

 

s

 

(increment

 

0.1

 

s)

3) [Ar.F]

 

Arc

 

Force

 

power

 

=

 

40%

 

(by

 

default)

a) 0[OFF]...

 

100%

 

(increment

 

1%)

4) [u.AF]

 

Arc

 

Force

 

trigger

 

level

 

=

 

12

 

V

 

(by

 

default)

a) 9...

 

18

 

V

 

(increment

 

1

 

V)

5) [CVS]

 

current

voltage

 

curve

 

slope

 

=

 

1.4V/A

 

(by

 

default)

a) 0.2...

 

1.8V/A

 

(increment

 

0.4V/A)

6) [Sh.A]

 

short

 

arc

 

welding

 

=

 

OFF

 

(by

 

default)

a) On
b) OFF

7) [BSn]

 

voltage

 

reduction

 

unit

 

=

 

OFF

 

(by

 

default)

a) On
b) OFF

8) [Po.P]

 

current

 

pulsing

 

power

 

=

 

OFF

 

(by

 

default)

a) 0[OFF]...

 

80%

 

(increment

 

1%)

Summary of Contents for PRO-160

Page 1: ......

Page 2: ...2 TIG LIFT arc striking function 13 4 3 Arc current fade in function 13 4 4 Pulsed current welding function 14 5 Semiautomatic metal inert active gas welding MIG MAG 15 5 1 Welding cycle MIG MAG 17 5...

Page 3: ...t 0 6 mm at most 1 75 1 5 115 2 155 2 5 195 4 310 6 465 3 mm 120 A at most 0 8 mm at most 1 5 75 2 105 2 5 130 4 205 6 310 4 mm 160 A at most 1 0 mm at most 2 75 2 5 95 4 155 6 230 PRO 200 3 mm 120 A...

Page 4: ...requency of voltage supplied to the transformer the transformer can be made several tenfolds smaller That is why weight and overall dimensions of this machine is several times smaller than those of re...

Page 5: ...oltage reduction unit on off on off on off on off MMA open circuit voltage V 12 75 12 75 12 75 12 75 Arc striking voltage V 110 110 110 110 Rated power consumption kW 4 0 4 6 5 5 6 1 6 9 7 9 6 9 7 9 M...

Page 6: ...n a manual metal arc welding with a stick electrode MMA b tungsten arc inert gas welding TIG c semiautomatic metal inert active gas welding MIG MAG 5 Machine operation indicator a permanent green ligh...

Page 7: ...MAG welding with solid wire cable of the feeder machine is connected c in case of semiautomatic MIG MAG welding with flux wire earth cable is connected B Power current socket of bayonet type a in case...

Page 8: ...3 4 hours Therefore do not switch the machine off in cold season if you are going to switch it on within 4 hours The machine must be placed to ensure free inlet and outlet of cooling air through vent...

Page 9: ...LDING Procedure for machine preparation to operation insert the electrode cable into the source socket insert the earth cable into the source socket B connect the earth cable to the work piece connect...

Page 10: ...be increased to maximum value for even better quality of the striking moment if the machine is operated from good power mains However keep in mind that boosted current of this function can burn throu...

Page 11: ...n can also be increased to maximum value for even better stability of short arc burning but this requires for better supply mains and increases the risk of work piece burn through The result is achiev...

Page 12: ...es 13 45 70 it is recommended although not required to set the slope CVS to 1 0V A On the other hand cellulose electrodes 1 4 even require for setting the slope CVS to 0 2 0 6V A and sometimes it is a...

Page 13: ...t are set to most common values of 5 0 Hz and 50 respectively In order to enable this function it is enough to set pulsing power Po P to a value above zero This parameter is set in percent of current...

Page 14: ...ct the earth cable to the work piece install pressure reducer on the gas bottle connect gas hose of the torch to pressure reducer of the gas bottle open the cock of the gas bottle and check it for tig...

Page 15: ...f arc striking This function is implemented by touching the work piece with the element The user can keep the electrode in this position for an unlimited time and when he she decides that he she is re...

Page 16: ...lsing frequency Fr P and mark to space ratio or duty ratio dut By default pulsing power Po P which is the key parameter is set to OFF position i e disabled while pulsing frequency Fr P and duty ratio...

Page 17: ...nal wire feeding machine In order to do that it must have its own supply source or be supplied by the source voltage this option is less desirable because such systems rarely provide good and stable w...

Page 18: ...see changeover sequence in paragraph 6 1 Control slot 8 on the rear panel provides control over switching the source on and off Connection diagram Contacts 1 and 2 are the only used contacts which ar...

Page 19: ...specific application 5 1 WELDING CYCLE MIG MAG See paragraph 6 1 for sequence of changing parameters of functions Time of pre purging t1 and post purging t2 with shielding gas is set on the wire feed...

Page 20: ...P which is the key parameter is set to OFF position i e disabled while pulsing frequency Fr P and duty ratio dut are set to most common values of 20 Hz and 50 respectively In order to enable this func...

Page 21: ...of the main parameter of the current welding mode on its digital indicator 1 in MMA mode arc current 2 in TIG mode arc current 3 in MIG MAG arc voltage Buttons 3 on the front panel serve to change the...

Page 22: ...formed for each mode individually It is designed this way for convenience so that the user does not reset customized settings of the remaining two modes 7 GENERAL LIST AND SEQUENCE OF FUNCTIONS MMA we...

Page 23: ...ng power OFF by default a 0 OFF 80 increment 1 3 Fr P current pulsing frequency 10 0 Hz by default a 0 2 500 Hz dynamic increment 0 1 Hz 1 Hz 4 dut mark to space ratio duty ratio is the ratio of large...

Page 24: ...plug Wait until internal circuits of the machine de energize about 5 minutes and only then proceed with other actions When leaving the machine install a restrictive plate which prohibits switching the...

Page 25: ...50 60 Hz 220 V Mains voltage variation range 160 260 V Efficiency ratio at rated current 92 Arc current adjustment range 8 160 A 10 200 A 12 250 Arc current at 5 min 70 LD 5 min 100 LD 160 200 250 13...

Page 26: ...g results in the following dangers injury of maintenance personnel or third persons damage of the machine or property of the enterprise derangement of efficient working process All persons dealing wit...

Page 27: ...GER OF MAINS AND ARC CURRENT electric shock can lead to death magnetic fields created by this machine can have adverse effect on operability of electrical appliances such as cardiac pacemakers People...

Page 28: ...le avoid installing the welding machine directly on the conductive coating of floor or work table use insulating pads SAFETY MEASURES IN NORMAL CONDITIONS Check the machine for external damages and pe...

Page 29: ...27 PATON PRO series DC MMA TIG MIG MAG Schematic electrical diagram of the Source PATON PRO 160 200 250 DC MMA TIG MIG MAG 220VAC...

Page 30: ...8 16 ACCEPTANCE CERTIFICATE Arc inverter rectifier PATON PRO 160 200 250 Serial number __________________________P has been approved for operation Sale date _____ _________________20____ Stamp here __...

Page 31: ...__________ Date of receipt for repair _____ _________________20____ __________________ signature Symptoms of non operability ______________________________________ Cause ______________________________...

Reviews: