background image

 

- 5 -

               

PATON 

ECO series

 DC MMA

 

 

PARAMETERS

 

ECO 

 315

 

ECO 

 400

 

Rated voltage of three-phase mains 50Hz, V 

3x380 

3x380 

Rated current consumption in one phase, A 

15,3 

22,2 

Rated arc current, A 

315 

400 

Maximum rms current, A 

390 

500 

Load duration (LD) 

45% / at 315A 

100% / at 210A 

45% / at 400A 

100% / at 265A 

Interphase voltage change limit, V 

±

15% 

±

15% 

Arc current adjustment range, A 

50 

 315 

60 

 400 

Hot-Start 

 

 

 

 

Arc-Force 

 

 

 

 

Anti-Stick 

 

 

 

 

Open-circuit voltage, V 

70 or lower 

 70 or lower 

Arc striking voltage, V 

110 

110 

Rated input, kVA 

10,1 

14,6 

Maximum input, kVA 

12,7 

18,7 

Efficiency, % 

90 

90 

Cooling 

forced 

forced 

Operating temperature 

–25 … +45ºС

 

–25 … +45ºС

 

Overall dimensions (length, width, height), mm: 

31

5 х 1

45 

х 2

95 

380 

х 1

45 

х 

295 

Weight, kg 

7,2 

8,7 

IP rating* 

IP21 

IP21 

 
*The casing of ECO series machines prevents getting of foreign bodies with a diameter 
greater  than  5,5  mm  inside  the  machines  and  protects  them  against  the  vertically 
dripping water 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for ECO Series

Page 1: ...PATON ECO series DC MMA 0...

Page 2: ...PATON ECO series DC MMA...

Page 3: ...ection 8 3 Manual metal arc welding MMA 8 3 1 Hot Start function 8 3 2 Arc Force function 9 3 3 Anti Stick function 10 4 Maintenance 10 5 Three phase generator operation 10 6 Storage 10 7 Transportati...

Page 4: ...re Do not earth by connecting to neutral conductor Electrode used Current strength Cross section of each phase conductor sq mm Max cable length m 2 mm 80A max 0 75 215 1 0 290 1 5 430 3 mm 120A max 1...

Page 5: ...for the same rated current Main advantages 1 Beside the surge protection the machine has a system regulating voltage in case of large long term change of interphase voltage from 320V to 440V 2 The ma...

Page 6: ...range A 50 315 60 400 Hot Start Arc Force Anti Stick Open circuit voltage V 70 or lower 70 or lower Arc striking voltage V 110 110 Rated input kVA 10 1 14 6 Maximum input kVA 12 7 18 7 Efficiency 90 9...

Page 7: ...nded length of power welding cables for welding Machine model Cable length m one way Cross section mm2 Cable brand ECO 315 1 10 25 KG 1 25 2 14 35 KG 1 35 3 20 50 KG 1 50 ECO 400 3 30 35 KG 1 35 5 45...

Page 8: ...structions in this operation manual WARNING Do not use the welding machine to defrost pipes 2 2 ENVIRONMENT The welding machine is protected against the penetration of solid foreign bodies with a diam...

Page 9: ...gulations The neutral conductor ground is prohibited 3 MANUAL METAL ARC WELDING MMA insert the electrode holder cable into the A source socket insert the ground terminal cable into the B source socket...

Page 10: ...by the controller is 90A The Hot Start current is 90A 33 120A Fig 3 HOT START function 3 2 ARC FORCE FUNCTION The advantages increased stability of welding with a short arc better transfer of metal d...

Page 11: ...ibiting to turn the machine on To ensure the normal operation of the machine for many years please follow a few rules carry out safety inspection according to the schedule see the Safety Rules section...

Page 12: ...ions are given on the identification plate on the top or rear panel In this case the mains plug and mains cable should be selected according to the voltage used Parameters ECO 315 ECO 400 Rated mains...

Page 13: ...erature meter malfunction Turn to the Service Center Difficult arc striking during MMA welding power source status indicator flashes green Phase to phase voltage at the striking moment is close to the...

Page 14: ...rea using special means ensure efficient supply of fresh air solvent vapors should not be in the welding arc zone SPARKS SPREAD HAZARD remove inflammable items from the working area welding on contain...

Page 15: ...nstructions on the welding machine are legible STRAY WELDING CURRENTS ensure that the ground cable terminal is firmly attached to the welding point if possible do not put the welding machine directly...

Page 16: ...15 PATON ECO series DC MMA 12 WIRING DIAGRAM Wiring diagram of PATON ECO 315 400 DC...

Page 17: ...a result of falling of the machine or falling of heavy objects on the machine falling out of buttons and connectors damaged due to corrosion broken down due to the impact of moisture on its power and...

Page 18: ...lost the data sheet if the seller did not fill in the data sheet when selling the machine or filled it in incorrectly warranty period is extended for a period of warranty service of the machine in the...

Page 19: ...____________________________________________ ____________________________________________________________________ Date of acceptance for repairs _________________ 20____ __________________ signature S...

Page 20: ...____________________________________________ ____________________________________________________________________ Date of acceptance for repairs _________________ 20____ __________________ signature S...