3.3 ANTI-STICK FUNCTION 

During the initial arc striking, the electrode can stick to the product, which can 

result in overheating and even damaging the electrode. 

If the electrode sticks to the product, the machine reduces the arc current after 

0.6...0.8  seconds.  This  makes  it  easier  for  the  welder  to  separate  (tear  off)  the 
electrode from the product without the risk of burning the eyes through an accidental 
arc striking. After the electrode is torn off the product, welding can be continued. 

 

4. MAINTENANCE 

WARNING! Before you open the machine for preventive maintenance, turn 

it  off  and  withdraw  the  mains  plug.  Let  the  internal  circuits  discharge  (for  5 
minutes)  first  and  then  proceed.  When  you  carry  out  maintenance,  put  a  sign 
prohibiting to turn the machine on. 

To ensure the normal operation of the machine for many years, please, follow a 

few rules: 

-

 

carry  out  safety  inspection  according  to  the  schedule  (see  the  Safety  Rules 
section); 

-

 

in  case  of  intensive  use,  blow  the  machine  through  with  dry  compressed  air 
once a year. 

Warning!

 Blowing through from a too short distance may damage 

the electronic components; 

-

 

if there is much dust, clean the cooling lines manually. 
 

5. GENERATOR OPERATION 

The power source can be fed from the generator if the following conditions are 

met: 

Electrode 

Current 

Min capacity of three-
phase generator, kVA 

Ø

80А

 max 

2,6 

Ø3

 

120A max 

4,1 

Ø4

 

160A max 

5,5 

Ø5

 

220A max 

8,3 

Ø6

 

315A max 

12,7 

Ø6

 

400A or less 

18,5 

 

WARNING!  For  trouble-free  operation,  the  output  phase-to-phase  voltage 

of the generator should be within the range of 320-440V! 

 

6. STORAGE 

The  packed  machine  removed  from  operation  should  be  stored  under  storage 

conditions 4 according to GOST 15150-69 for 3 years. 

Summary of Contents for ECO Series

Page 1: ...PATON ECO series DC MMA 0...

Page 2: ...PATON ECO series DC MMA...

Page 3: ...ection 8 3 Manual metal arc welding MMA 8 3 1 Hot Start function 8 3 2 Arc Force function 9 3 3 Anti Stick function 10 4 Maintenance 10 5 Three phase generator operation 10 6 Storage 10 7 Transportati...

Page 4: ...re Do not earth by connecting to neutral conductor Electrode used Current strength Cross section of each phase conductor sq mm Max cable length m 2 mm 80A max 0 75 215 1 0 290 1 5 430 3 mm 120A max 1...

Page 5: ...for the same rated current Main advantages 1 Beside the surge protection the machine has a system regulating voltage in case of large long term change of interphase voltage from 320V to 440V 2 The ma...

Page 6: ...range A 50 315 60 400 Hot Start Arc Force Anti Stick Open circuit voltage V 70 or lower 70 or lower Arc striking voltage V 110 110 Rated input kVA 10 1 14 6 Maximum input kVA 12 7 18 7 Efficiency 90 9...

Page 7: ...nded length of power welding cables for welding Machine model Cable length m one way Cross section mm2 Cable brand ECO 315 1 10 25 KG 1 25 2 14 35 KG 1 35 3 20 50 KG 1 50 ECO 400 3 30 35 KG 1 35 5 45...

Page 8: ...structions in this operation manual WARNING Do not use the welding machine to defrost pipes 2 2 ENVIRONMENT The welding machine is protected against the penetration of solid foreign bodies with a diam...

Page 9: ...gulations The neutral conductor ground is prohibited 3 MANUAL METAL ARC WELDING MMA insert the electrode holder cable into the A source socket insert the ground terminal cable into the B source socket...

Page 10: ...by the controller is 90A The Hot Start current is 90A 33 120A Fig 3 HOT START function 3 2 ARC FORCE FUNCTION The advantages increased stability of welding with a short arc better transfer of metal d...

Page 11: ...ibiting to turn the machine on To ensure the normal operation of the machine for many years please follow a few rules carry out safety inspection according to the schedule see the Safety Rules section...

Page 12: ...ions are given on the identification plate on the top or rear panel In this case the mains plug and mains cable should be selected according to the voltage used Parameters ECO 315 ECO 400 Rated mains...

Page 13: ...erature meter malfunction Turn to the Service Center Difficult arc striking during MMA welding power source status indicator flashes green Phase to phase voltage at the striking moment is close to the...

Page 14: ...rea using special means ensure efficient supply of fresh air solvent vapors should not be in the welding arc zone SPARKS SPREAD HAZARD remove inflammable items from the working area welding on contain...

Page 15: ...nstructions on the welding machine are legible STRAY WELDING CURRENTS ensure that the ground cable terminal is firmly attached to the welding point if possible do not put the welding machine directly...

Page 16: ...15 PATON ECO series DC MMA 12 WIRING DIAGRAM Wiring diagram of PATON ECO 315 400 DC...

Page 17: ...a result of falling of the machine or falling of heavy objects on the machine falling out of buttons and connectors damaged due to corrosion broken down due to the impact of moisture on its power and...

Page 18: ...lost the data sheet if the seller did not fill in the data sheet when selling the machine or filled it in incorrectly warranty period is extended for a period of warranty service of the machine in the...

Page 19: ...____________________________________________ ____________________________________________________________________ Date of acceptance for repairs _________________ 20____ __________________ signature S...

Page 20: ...____________________________________________ ____________________________________________________________________ Date of acceptance for repairs _________________ 20____ __________________ signature S...

Reviews: