48
Wireless Data Communication System - WD PRO Series Instruction Manual
8. Function Details
8.2.1 Determine Signal Tower Control Input Function
There are two types for determining Signal Tower control line inputs, [Normal] and [Flashing]. Select the setting in
WDS-WIN01. If there is no flashing state to get, use [Normal].
Setting*
1
Determination
Description
Normal
Light on
When the Signal Tower control line input status changes OFF→ON, the result is
"light on" and the information is transmitted.
Light off
When the Signal Tower control line input status changes ON→OFF, the result is
"light off" and the information is transmitted.
Flashing
Determination*
2
*
3
Flashing
When the Signal Tower control line input status repeatedly alternates
ON→OFF→ON→OFF..., the result is "flashing" and the information is transmitted.
Select from the following 3 determination speeds in WDS-WIN01.
・
Flashing (short)
・
Flashing (medium)
・
Flashing (long)
Light on
When the Signal Tower control line input status changes OFF→ON, the result is
"light on" and the information is transmitted.
Light off
When the Signal Tower control line input status changes ON→OFF, the result is
"light off" and the information is transmitted.
* 1 The default setting is [Normal].
* 2 Flashing is determined when there are two status changes within a defined period. This period is called "SS seconds". You
can select "SS seconds" from three different time periods.
* 3
There is not [Flashing] status in the buzzer signal. When determined as flashing, the buzzer on information is transmitted.
8.2 Contact Input Line Functions
・
Flashing (short): SS seconds = 0.7 seconds
・
Flashing (medium): SS seconds = 1.5 seconds
・
Flashing (long): SS seconds = 2.5 seconds
Light off (buzzer off)
Shorter
than SS
Shorter
than SS
Shorter
than SS
Shorter
than SS
Light flashing (buzzer on)
Result
Input
O N
OFF
・
The status and determination operations are as follows. Information in brackets "( )" represent buzzer operation.
Setting
Determination
Description
Change in state
Operation result
Normal
Light on
Light off → light on
O N
OFF
Light off (buzzer off)
Light on (buzzer on)
Result
Input
100 ms or longer
Light off
Light on → light off
Light on (buzzer on)
Light off (buzzer off)
Result
Input
O N
OFF
100 ms or longer