3.2.2.6.
<Turn off Signal Tower light and stop the buzzer>
Sending ASCII data in the following form will control the Signal Tower light to turn off and stop the buzzer.
[Transmission Example]
In this example
, the Signal Tower lights are turned off and the buzzer is stopped.
• Send Data
Header
ID
Command
End Code
@
[40H]
?
[3FH]
?
[3FH]
C
[43H]
!
[21H]
• Reply Data
Normal Response
Data
ACK
[06H]
Response Error
Data
NAK
[15H]
The following are conditions in which will get a NAK reply, and the error contents are as follows.
Transmission Condition
Error Contents
Command Error
When commands other than a command from the list are specified
Data size error
When the number of bytes in the send data is different
Timeout
When the reply interval for every byte exceeds 5 seconds after receiving a header
*Do not transmit the following command, before this product transmits reply data. It may not operate
normally.