background image

-10-

-7-

1. Confirm the hole position on the product.
2. Secure the template to the installation surface 
    using adhesive tape.
3. Mark the installation holes using nail punch,

 etc.

4. Drill the holes in the  installation surface.

 Confirm the direction of the name plate and

       the wiring route before you drill the holes.

Using this template

4. Installation 

 Mounting

 Drill mounting holes in the wall. (See the following  installation diagram.)

 Secure the mounting bracket with the hex bolts and hex nuts.

 ●

 Install the Signal Tower vertically at a location that has sufficient strength and minimal

  

 vibration.

 ●

 The alarm of buzzer models can be heard best from the front direction.

  

 Therefore make sure the Signal Tower is facing the correct direction before install it.

 This product can be used only indoors. (Do not use it outdoors.)

 Do not install the Signal Tower horizontally or inverted. 

 

 (See the following "Mounting side" .)

 Make sure of the specified operating voltage and current before use.

 Do not use or keep without LED unit or Head cover installed.

 Use the soft cloth with moisture when the LED unit or Bse unit must be

 

 cleaned up. (Do not use thinner, benzine, gasoline or oil.)

 During installation, do not remove the waterproof sheet. It may cause

 

 a malfunction of water proof structure.

 This product has 1mm thick waterproof packing at the bottom of the pole

 

 bracket. However, when complete waterproofing is not provided due to the

 

 unevenness of the installation surface, apply waterproof sealant between the

 

 unit and the installation surface to maintain waterproof conditions.

 When the cable gland is used, the hole must be the dimension that it can go 

    through. The cable which it can be used for is as follows;
    Screw Size: M16×P1.5,  Screw Length: Maximum 11mm,  
     Outer Diameter: Maximum 25mm,   Material: Plastic. 

Caution

5. Wiring Procedure

Wiring procedure

 (Concerning the mark 

, the conditions about the product corresponding to UL are mentioned.)

Please make wiring connection according to wiring example.

 For wiring of 5 layers or less, please make wiring connection by increasing or decreasing external contacts in each layer according

 to wiring example.

 When using multiple LED units of the same color, make the contact capacity equal to the number of same color LED units multiplied

 by the contact capacity for 1 light.   (This is because LED units of the same color light up for one signal line.)

Fuse for protection of external contact should be installed within 305mm from the connected point of the power source wire.

 When wiring is completed, insulate the end of each unused lead wire by using insulation tape.

Use "Class 

 Circuit" for the power supply source. Concerning fuse and fuse-holder, be sure to use the products authorized

by UL Inc.

Use the fuse conforming to the rated current of the machine.  ( Example : Class J type fuse )

 For the 90

250V AC model, connect the green/yellow lead wire to the ground.

 If you have any questions about simultaneous use of multiple units or other special operations, 

     contact PATLITE Customer Service before wiring.

Unit

mm

Mounting hole

3-

φ

5

Name plate

Buzzer

transmission

direction

Installation
template

5-1. Wiring example for Base unit [Terminal block]

CN4:

For high voltage 

 (90-250V type)

Tighten torque 0.6N

・m

CN2:

For signal and low voltage (24V type)

CN5:

For Earth

 ( Tighten torque : 1.2N

m )

1
2
3
4
5
6
7
8
9

10

Terminal

No.

Red

Orange

Green

Blue

White

Gray

Black

Yellow

Gray

Black

Front

Terminal

color

LED unit Red

LED unit Amber

LED unit Green

LED unit Blue

LED unit White

Buzzer1

Pi

(Continuous)

Buzzer2

Pi

Pi

Power supply(Continuous COM)

Flashing COM

Power supply

Corresponding unit

or operation

Recommendable wire type / dia

UL1007AWG22

~16

 Recommendable wire type / dia

UL1015AWG18

14

 Strip length of lead wires: 10mm

 Recommendable wire type / dia

UL1015AWG18

14

 Use the lead wire with the color of green or green/yellow for the earth wire.

UL1430AWG22

~16

MIN

MAX

VOL.

Front

Bottom

  

 Please use a fuse specified by IEC 127.

  

 When lead wires are exposed outside the body during pole installation, etc. always provide double insulation using insulation tape

  

and vinyl tubing, etc.

  

 For the 90-250V type, use shielded cable for the power supply cable and be sure to connect the shield to ground (CN5).

  

 Do not turn the volume control forcibly.

  

It might damage the volume control.

7. Volume adjustment

8. To use this product in accordance with the CE marking, please observe the followings

 You can adjust the volume by turning the volume control at the bottom to the left or right.

Body

Volume

Caution

9. Specifications

  

 In the event that the tower is subject to continuous,excessiv shaking,vibration may be too strong and there is a danger

      of breakage. Immediately stop using the tower and consult PATLITE Customer Service.  
  

 PATLITE Corporation disclaims all liability for any malfunction or damage occurring as a result of handling contrary to

  

the instructions, cautions and warnings mentioned in this manual.

  

 Specifications may change without notice due to continual product improvement.

Caution

LU7-02

LU7-02FB

LU7-M2

LU7-M2FB

24V DC

Mass

Model

Rated voltage

Power

consumption

Base unit

90

250V AC

(50/60Hz)

LU7-E-R

LU7-E-A

LU7-E-G

LU7-E-B

LU7-E-C

24V DC

Mass

Model

Rated voltage

Power

consumption

LED unit

Flashing cycle and

 Peak sound level

FB Type

60 Flashes

per minute

Sound level

70

90dB/m

   

FB type only

1.2W

Buzzer

2.2W

Standby power
consumption

1.0W

250g

275g

350g

375g

1.3W

1.0W

60g

60g

Use 75

 CU Wire only.

Upright

Invert

Horizontal

 Strip length of lead wires: 9mm

VOL.

VOL.

VOL.

 Remove Body from Base unit.(In case of 24V type, refer to "6. Unit reformation" .)

 In case of 90-250V type, refer to "5-1-2. Wiring procedure for 90-250V type,"  Be sure to disengage the Screw before removing 

    the Body from Terminal block.

Turn the power OFF before performing unit reformation.

First make sure the O-ring is mounted as shown in Drawing 1,then align the locating mark of each unit,and place the units together in 
the direction of the arrow (

) as shown.

Rotate the upper unit in the direction of the arrow(

).(Refer to Drawing.2)

For 90-250V type Base Unit, tighten the Screw that secures the Body to the Terminal block.

6. Unit reformation

Caution

Do not remove a LED unit forcibly.

     It may damage the unit.

Do not warp or damage the LED unit to a lower unit.

Make sure the O-ring is first mounted in position on 

     the Terminal block as shown in Drawing 1, 
     then place the Body on the O-ring.

If the Body is mounted to the Terminal block, do not 

attempt to rotate either part with the Screw pushed in or 
engaged.

Never attempt to tighten the Screw until the locating 

mark is aligned with the arrow as shown in Drawing 2.

[Mounting side]

Terminal block

Drawing.1

Drawing.2

1

2

2

a

Drawing.3

O ring

Never fail to observe the strip length of lead wire. Excessively short strip length causes 
connection failure and excessively long strip length gives rise to electric shock or short 
circuit, which are extremely dangerous.

While wiring this product, take care to avoid short-circuits from loose wire strands or 
similar conditions.

Do not use unnecessarily strong force to separate the Terminal block and the Body.

    Inside wiring may be damaged and may cause failure.

Connect high-voltage power supply cable to the specified terminals in the Terminal block.
Failure to connect this cable correctly will burn out the internal circuit.

Caution

[Vibretion resistance]

1-Lights

4.5G   44.1m/s

2

4.5G   44.1m/s

2

2-Lights

3.5G   34.2m/s

2

4.5G   44.1m/s

2

3-Lights

2.0G   19.6m/s

2

1.9G   18.6m/s

2

10-150Hz

4-Lights

1.3G   12.7m/s

2

1.9G   18.6m/s

2

5-Lights

0.7G   6.8m/s

2

1.0G   9.8m/s

2

5-Lights

1.9G   18.6m/s

2

1.9G   18.6m/s

2

40-150Hz

Number of 

LED units

LU7-02

LU7-M2

Allowable vibration

frequency

 Wire Exit(φ18)
※When cable gland is used(φ23)

φ40

13

3