Troubleshooting
Below are some potential causes and countermeasures to the symptoms indicated in bold. Please contact your retailer or
certified technician for service & repair.
Below are some potential causes and countermeasures to the symptoms indicated in bold. If still unable to resolve issue, please
contact your retailer or certified technician.
Will Not Light
1. Air in gas line. If new install, may take several attempts to purge air
2. Debris in gas line. Confirm gas line is clear (insulation, dirt, plastic, excessive pipe sealer etc..)
3. Gas Pressure Improper Confirm proper gas pressure found (Section 1)
4. Spark Igniter needs adjusted Spark Igniter Must be correctly aligned with burner holes.
5. Weak Batteries Replace batteries.
6. Wire is shorted Re-route wire away from conductive materials.
Will Not Stay Lit
1. Gas Pressure Improper Confirm proper gas pressure found (Section 1)
2. Improperly applied media Review Media in (Section 5)
Noise
1. Whistling Sound
Change Flex line routing.