Ground Level (Earth)
D
.875 TYP. (usable flat lip)
*
*
A
B
C
SPECIFICATIONS
Model:
Propane Gas (LP)
A
Pan
Depth
B
Min./Max.
Install Opening
C
Inside
Pa
n
D
Ground
Level
E
Side
Wall
F
Combustible
Ceiling
G
Combustible
Floor
FPB-G16RBSMT-P01
2.500”
16.5”/17.25”
15.875”
8”
14”
57”
15.5”
FPB-G16RBSMT-P02
2.500”
16.5”/17.25”
15.875”
8”
14”
57”
15.5”
Table1. Fire Pit Dimensions
Figure 1. Fire Pit Dimensions; refer to Table 1.
(Dimensions applicable to round or square pans)
Table 2. Btu Specifications
Figure 2. Clearance to Combustibles
(Not to be used in an enclosed space)
Disclaimer:
Btu listings are based on 7.0”WC for Natural Gas and 11.0”WC
for Liquid Propane (LP) at the inlet side of the gas valve. Flex line size and
proper gas pipe sizing will also affect Btu’s. As a result your Btu’s may vary
slightly from Table 2 specifications.
Table 3. Gas Pressures
G
E
F
Model:
MT Propane (LP)
LP Factory
Orifice
BTU’s
Natural/Propane
FPB-G16RBSMT-P01
#43
55,000
FPB-G16RBSMT-P02
#43
55,000
Pressure
NG
LP
Min. Inlet
3.5” WC
8.0” WC
Max. Inlet
10.5” WC
13.0” WC
Normal Inlet
7.0” WC
11.0” WC