Pathway Connectivity
11
QUATTRO Manual
November 2018
Utilities
Property
Explanation
Available Settings
Reboot
Power cycle the gateway
Factory Default
Resets patches and all
properties except the IP
settings to factory values.
Includes properties, such as
signal loss, that are set from
Pathscape.
Factory Default Including
Network Setup
Resets patches and all
properties including the IP
settings to factory values.
Includes properties, such as
signal loss, that are set from
Pathscape.
<Back>
Note Regarding ArtNet, Shownet and Subnet Mask
The ArtNet protocol is explicitly sent to a broadcast address, typically
2.255.255.255 or 10.255.255.255. The QUATTRO must have its subnet mask set
wide enough to include this broadcast address. When using ArtNet, a Class A
subnet mask of 255.0.0.0 is recommended to ensure DMX output.
Shownet is explicitly sent to 192.168.1.255. On most Shownet systems, an
QUATTRO should use an IP of 192.168.1.x and a subnet mask of 255.255.255.0.