background image

Installation Guide

10/21/21

The  PWPP  RM  P8  operates  on  wall  power,  accepting  an  input 

voltage between 100-240VAC at either 50 or 60 Hz. The AC outlet 

shall be near the equipment and shall be easily accessible. There 

is no on/off switch. This equipment relies on building installation 

overcurrent protection.
Once powered up, the PWPP RM P8 is ready for use.
The PWPP RM P8 is designed for installation in a standard EIA 19” 

rack, with the LCD and encoder facing out. Attach the rack ears 

(included) to either side of the enclosure using the Phillips screws 

provided (two per ear). Attach the PWPP RM P8 to the rack using 

standard rack screws (not included).
Wall (PWACC WMLG) and truss mount (PWACC TMLG) adapters 

are available as accessories.

See the Pathscape website under “Pathport Rack-mount” to 

download the Product Manual for additional information.

PATHPORT RACK-MOUNT 8-PORT 

(PWPP RM P8)

Due to new cybersecurity laws, all Pathport devices shipped after 

January 1, 2020 have security properties enabled. This means 

that by default, the device is not set up to receive unsecured 

network protocols such as Art-Net, E1.31 sACN, ShowNet, NET2 

or Pathport Protocol.

You must add the Pathport to a Security Domain using 

Pathscape before configuration and use.

Pathway ssACN (Secure sACN) is enabled by default.
To  use  the  above  unsecured  protocols,  open  Pathscape.  In 

the Pathport base device properties, under the 

Network DMX 

Receive Protocols 

section,  click  the 

Allow Unsecured RX

 

checkbox. 

 

Once checked, you may select the network protocol(s) to receive.

For further information, please see the following sections in the 

Pathscape

 manual: 

Security

Pathport Properties >

 

Network 

DMX Receive Protocols .

IMPORTANT - UNSECURED NETWORK PROTOCOLS

PWPP RM P8 and PWPP RM P4 devices running firmware V6.1 

and later

 will show a 

Security Mode

 screen when first powered 

on.

Choose the Security Mode

 from the front panel using the encoder 

knob. 

Security Mode

Wait for Pathscape to Secure

Local Configuration Only

Disable Security

If adding to a Security Domain in Pathscape, no input here is 

needed. Open 

Pathscape

 on a PC on the same network as the 

gateway and add it to a 

Security Domain

.

If  using  the  gateway  from  the  front  panel  only,  select 

Local 

Configuration Only

 (Read-Only) mode. The device will only be 

configurable from the Front Panel; configuration from Pathscape 

is disabled.

If 

opting out of Security features

, select 

Disable Security

. The 

device will be configurable using Pathscape from any PC on the 

network (even by unauthorized parties), as well as the front panel.
The system is now ready for configuration and testing.

See PWPP RM P8 or PWPP RM P4 manual for further details.

You must select a Security Mode and manually enable 

unsecured protocols before use.

If the device is set to 

Local Configuration Only

 (Read-Only) 

mode or security is 

Disabled

, Pathway ssACN is not available 

for use.

If the device is 

secured via Pathscape and part of a Security 

Domain

, Pathway ssACN (Secure sACN) is enabled by default, 

all others must be manually enabled.
Enable desired protocols in the same manner as shown above.

Devices set to 

Local Configuration Only

 mode must enable 

protocols using the front panel encoder and display.

See the respective PWPP RM P8 or PWPP RM P4 manual for 

instructions on using the front panel display and encoder for 

menu navigation and configuration of settings

.

IMPORTANT - SECURITY MODE 

(RACK-MOUNT MODELS)

NETWORK PROTOCOLS 

(RACK-MOUNT MODELS)

Reviews: