Model 1003 12-Relay  

Contact Closure

Manual

1003-300-REV1

04/04/19

TM

Pathway Connectivity Solutions

 

#103—1439 17Avenue SE Calgary AB

 

Canada T2G 1J9

[email protected] 

www.pathwayconnect.com

 

tel (403) 243-8110 fax (403) 287-1281

• 

Power input: 9-30VDC, 6W maximum

• 

250V Fault protection on DMX input

• 

1500V Opto-isolation between DMX input and module 

electronics

• 

Connections (DMX): 

• 

Compression Fit (Screw Terminal): stranded, 14-30 AWG

• 

IDC Connector: Cat5/6 or solid wire, 22-24 AWG

• 

Input Signal: ANSI E1.11 DMX512-A, ANSI E1.20 RDM

• 

Outputs: 12 normally-open/normally-closed, isolated con

-

tacts

• 

Contact rating: 2A @ 30VDC

Exceeding this rating may result in personal injury or 

damage to this and other connected devices.

ELECTRICAL INFORMATION

• 

USITT DMX512 - 1990 / ANSI E1.11 DMX512-A 

R2013

• 

ANSI E1.20 RDM(2010) - Remote Device 

 

Management

• 

RoHS 2011/65/EU

• 

CE

COMPLIANCE

DMX rules require the last device on a DMX line to be 

terminated with a 120Ω resistor between pins 2 and 

3 to prevent signal reflection. If there is no connec

-

tion to the DMX THRU terminals, the DMX Terminate 

switch should be ON. 
If there are other devices connected to the DMX THRU terminal, the 

DMX Terminate switch should be OFF and termination be applied to 

the final device in the daisy-chain.