5.1.1 Slewing Angle Limitation / Work Area Definition
Programmable function for the limitation of the left and/or right slewing angle or working area
definition.
Call function:
Call LIMIT Setting.
Enter the corresponding figure to call the function:
Slewing angle limitation
(Maximum/Minimum
Slewing
Angle)
( Chapter 5.1.1.A)
Work Area Definition
(Virtual wall setup. A wall is
defined by a straight line between
two set points.)
( Chapter 5.1.1.B)
5.1.1.A
Slewing Angle Limitation
set / delete left slewing angle:
Select limit:
Select left limit
set:
delete:
Position boom to
required left limit
value.
program
present slewing
angle as left limit
delete left
angle limit
quit
function