21
CODE
DESCRIPTION
CORRECTIVE ACTION
SP Ot
Internal
overheat
•
Open the access panel to the spa pack
(below the control panel) and allow
two hours to cool down
•
Reset GFCI breaker
Low-Level Settings
The spa pack – located inside the spa below the
topside control panel – has a service panel used to
set your spa’s low-level programming options. During
troubleshooting, you may need to check or reset these settings.
Note
: If your spa comes with a stereo, unplug the orange Di plug
on the top right corner of the pack during any of these steps.
Resetting the Spa Pack –
To reset the spa pack, press the Select
button twice.
Breaker current setting
– To adjust the breaker current setting (Br),
press the Select button and then press the Change button. The
normal current settings are:
For 240V 60Hz spas:
Br = 40
For 240V 50Hz 1
φ
spas:
Br = 1P
For 240V 50Hz 2
φ
spas:
Br = 2P
For 240V 50Hz 3
φ
spas:
Br = 3P
Low-level setting
– To reset the
low-level setting (LL), press and
hold down the Select button for
5 seconds. Use the Change
button to set LL=(see below)
even if it is the present value.
Press Select to save.
For Veneto (model 1301), LL=01
For Roma (model 1302), LL=05
For Amore (model 1303), LL=01
For Tuscany (model 1304), LL=05
For Sicilia (model 1305), LL=05
Note:
Wait 10 minutes and plug
the orange Di plug back in.