Pass XP-32 Owner'S Manua Download Page 7

7

The hand remote uses a multi-button direct access architecture.  This remote 

is designed to function with and operate several pieces of Pass Laboratories 

electronics.  Not all functions available on this hand remote will be applicable to 

your Pass Laboratories, XP-32.  The Remote operation is or should be very intuitive 

in operation; we have attempted to its operation as familiar as possible.  Where 

applicable the remote mirrors the front panel control of the XP-32.

HAND REMOTE

POWER: Power buttion is not used with the XP-32.

MUTE: Pressing mute once will quiet the pre-amp outputs; pressing mute a second 

time returns the XP-32 to the previous volume control settings

INPUT SELECTION: Pressing 1,2,3,4,5 will immediately move the input to that 

input selection and the volume and balance settings remain as they were, un-altered.

TAPE:  Pressing the tape button selects the tape loop and displays INPUT TAPE t 

with volume at 000. 

BALANCE: Pressing balance left (<) or balance right (>) will increase the level in 

the right or left speaker depending upon button is pushed

VOLUME:  Pressing the increase (^) button or the decrease (v) button will shift the 

volume setting in both channels equally in 0.5 steps.  Holding either button down 

will increase or decrease the level, until such time as you either release the button or 

reach the limits of the volume control.

PASS THRU:  Pressing this button once selects the Pass-Thru input and displays 

“PASS THRU” and swiftly ramps the volume from step 0 to step 179.  As a 

precaution pressing any command during this ramp up sequences, aborts the ramp 

up and sets the level to 000 in both channels immediately.  At this point  commands 

are locked and un-responsive.  This locking of commands is intentional and included 

to help avoid excessive and potentially dangerous play back levels. Pressing “Pass 

Thru” a second time exits “pass-thru” and un-locks other command functions..

DISPLAY: There are three brightness settings on the display selectable from either 

the hand remote or the front panel of the Control unit: Bright, Dim and Off.  The 

default setting for the display is “bright”.  Pressing the display button on the hand 

remote or the “mode” button on the front panel  steps through the 3 possible 

settings. 

When “off” is selected any other control function will cause the display function to 

illuminate and show the products operational status for approximately 7 seconds.  

Summary of Contents for XP-32

Page 1: ...1 PASS TM XP 32 Owner s Manual ...

Page 2: ...roductweurgeyoutochooseonethatis fully safety rated by the necessary local authority Power Cord Protection Power supply cords should be routed so that they are notlikelytobewalkedon abraded orpinchedbyitemsplacedonoragainstthem paying particular attention to cords where they enter plugs or exit from a device Never under any circumstance insert a cut or damaged power cord into a mains power socket ...

Page 3: ...ower supply dedicated to the control architecture The use of three fully independent power supplies in the control chassis results in dramatically lower radiated noise and far better THD Noise figures in the gain stages Residual circuit noise becomes paramountatlowsignallevels Bygoingtoextremelengthstolowernoiseweenjoy better resolution and dynamics in the music Inthetwogainchassiswecontinuetouseo...

Page 4: ...els may be placed in proximity of the power supply control unit either on top of or underneath with negligible loss of performance due to the extensive shielding afforded the power supply Some separation of the chassis is however encouraged The umbilical cables as supplied are 1 5m 5ft in length to allow for convenient component placement The XP 32 draws roughly 70W of power in operation The pre a...

Page 5: ...in output by use of the small volume control knob on the gain channels Once set both main and slave outputs track each other through the main volume controlonthecontrolchassis Havingtwoavailableandrelativelyindependentoutputswith asinglevolumecontrol allowsforbi ampingusingamplifiersofdifferentgainordriversof different sensitivity The output of the Tape loop is at 0dB unity gain output which allow...

Page 6: ...eforeselectingthehometheaterpassthrough passthruonthehandremote for thefirsttime itisimperativethattheinputdeviceontheHTinputhaveit sgainset to zero Failure to follow this precaution could result in a volume level intolerable tobothearsandspeakers Selectinghometheaterbypass setsthegainofthepre amplifier to 0dB gain of 1x When the Pass Thru function is selected volume control of the system is under...

Page 7: ... Pressing the increase button or the decrease v button will shift the volumesettinginbothchannelsequallyin0 5steps Holdingeitherbuttondown willincreaseordecreasethelevel untilsuchtimeasyoueitherreleasethebuttonor reach the limits of the volume control PASS THRU Pressing this button once selects the Pass Thru input and displays PASS THRU and swiftly ramps the volume from step 0 to step 179 As a pre...

Page 8: ...connector on the rear of the XP 32 control chassis This is intendedtosupplyatriggervoltagethatwillturnonassociatedequipmentsuchas poweramps Asperconvention voltageisappliedtothetipcontactand voltage isappliedtothesleevecontract Checktheownersmanualofyourpre amptoseeif this function in compatible The hand remote is powered by 2 each AAA batteries that are housed under the rearcoverofthehandremote B...

Page 9: ...n North American product must be returned to the country of origin for warranty service ForeigndistributorsareonlyrequiredtoofferwarrantyserviceonPassLaboratories product that they have imported verifiable by serial number Please note Conditions of warranty service and customer rights for product purchased outsidetheUnitedStatesmayvarydependinguponthedistributorandlocallaws Please check with your ...

Page 10: ... Auburn CA 95602 voice 530 878 5350 fax 530 878 5358 web passlabs com XP 32 Specs Power consumption 70 watts Gain 9 6 dB Balanced Output Impedance 25 Ohms RCA 50 Ohms XLR Input Impedance 22K Ohms Frequency response 0 05 dB 20Hz to 20KHz 2dB 150KHz Crosstalk 110dB THD 0 001 1V 1Khz Max out 23V RMS 0 1 Residual Noise 500nV RMS SN 150dB ref max out Dimensions 17 w x 12 5 d x 4 h times three Weight 62...

Reviews: