Maintenance:

Leave it on or turn it off: 

The product is designed to be left on all the time. The 

exception to this might be a case where the preamp will not be used for an extended 
time - in that case it can be turn off.

Cleaning: 

The fi nish can be damaged by harsh cleaners and abrasive cloths. We 

fi nd a damp soft cloth works best. You can also use a mild solution of windex or white 
vinegar but be careful to avoid the acrylic window. The acrylic window should only 
be cleaned using “plastic cleaner & polish”.

Remote batteries:

 The two AAA batteries should be replaced every six months at 

least. The batteries are located under the remote back. This is held in place with four 
4-40 phillips fl at head screws. Please note the polarity of the batteries, putting them in 
wrong could cause damage.

Replacing the fuse:

 The fuse should only be replace with the same type and size as 

indicated on the rear. Audio Specialty FUSE: NOTE: The “Overload” and “Time Delay 
characteristics” will differ slightly (due to the different metallurgy of the fuse elements) 
between commercial grade and audio grade fuses. We can’t guarantee that 
your audiophile grade fuse, won’t blow at a different in-rush current threshold, than 
your stock commercial fuse. Use of other than approved fuses, may invalidate your 
product warranty and result in product damage.

XP-22 Specs: 

Power consumption:  

 

 

40 watts

Gain:   

 

 

 

 

9.6dB Balanced

Output Impedance:  

 

 

25 Ohms RCA, 50 Ohms XLR

Input Impedance:   

 

 

22K Ohms

Frequency response:  

 

 

+/- 0.05 dB 10Hz to 20KHz, -2dB @ 150KHz

Crosstalk  

 

 

 

 

> 100dB

Residual Noise  

 

 

 

2uV RMS, SN -125dB ref max out

THD    

 

 

 

 

< 0.001 @ 1V 1Khz

Dimensions:    

 

 

 

17”w x 12.5”d x 4”h times two

Weight: 

 

 

 

 

40 lbs

How to replace the fuse:

Summary of Contents for XP-22

Page 1: ...1 pass XP 22 Owner s Manual ...

Page 2: ...stroy equip ment Ventilation Power amplifiers run warm but you should be able to place your hands on them without discomfort You must allow for this heat in installation by providing for free air circula tion around the product Leave a minimum of 6 of space around the amplifier The ventila tion should not be impeded by covering the ventilation openings with items such as newspa pers table cloths cur...

Page 3: ... transformer both electrically and mechanically The power supply circuitry itself is also lower noise and has additional filtering a little more complicated but worth it The XP 22 uses the single stage volume control borrowed from the XS line preamp This gives us one hundred 1 dB steps with lower noise and distortion while removing some signal path parts The gain circuitry continues to use our favo...

Page 4: ...on top of the power supply but for the best performance they should be separated a little Putting the power supply on a lower shelf works great The preamplifier s voltage and current rating are indicated by affixed tag on the rear of the preamplifier The preamplifier typically draws 45 watts during operation Please verify that the indicated voltage requirement of this preamplifier is consistent with th...

Page 5: ... is linked with the Home Theater Unity Gain function The HOME THEATRE FUNCTION is discussed at length later in this manual The two select arrows logically control selections of the various inputs to the preamplifier Before selecting the theatre pass through pass thru option it is imperative that the input device on input number 5 has its gain set to minimum Failure to follow this precaution could r...

Page 6: ...90dB range and is driven by a micro controller that reads the optical encoder serving as a front panel volume control In this manner tracking of the volume of the two balanced channels is possible with accuracy unavailable on any ordinary volume control assuring precise level steps and high common mode rejection in balanced circuits Wayne Colburn s exceptional volume control in conjunction with th...

Page 7: ... Pass Thru Pushing this button twice sets the pre amplifier to volume step 89 0 dB and input 5 As an added precaution when pass through is selected the volume ramps upto 89 This is to prevent nasty surprises when pass thru is selected accidentally The ramp up sequence can be stopped at any time by hitting any button on the remote The button must be pressed again to exit Pass Thru and unlock the oth...

Page 8: ...of the batteries putting them in wrong could cause damage Replacing the fuse The fuse should only be replace with the same type and size as indicated on the rear Audio Specialty FUSE NOTE The Overload and Time Delay characteristics will differ slightly due to the different metallurgy of the fuse elements between commercial grade and audio grade fuses We can t guarantee that your audiophile grade f...

Page 9: ...factory or shipping product to the factory for repair Non North American product must be returned to the country of origin for warranty service Foreign distributors are only required to offer warranty service on Pass Laboratories product that they have imported verifiable by serial number Please note Conditions of warranty service and customer rights for product purchased outside the United States ...

Page 10: ...1 0 pass Pass Laboratories Inc 13395 New Airport Rd Suite G Auburn CA 95602 530 878 5350 passlabs com ...

Reviews: