Now that the source component is connected, make sure there is no 
signal coming from it, probably by turning the volume all the way 
down.

With the speakers connected, make sure the power cord is attached 
and plugged into mains power; push the front panel button to 
activate the amplifier.  The “Power” LED will come on.

Do everybody a favor and try not to have shorted output cables.  It 
happens accidentally all the time, and the amplifier is designed to 
survive, but why tempt fate.  If  you accidentally cause the breaker 
to trip, it can be reset by first cycling the breaker handle to the off  
position (down) and then on (up).  The fault, which caused the 
“trip”, will need to be corrected prior to resetting this breaker. 

Of  course it’s always possible that something may go wrong.  If  so, 
don’t get excited.  It’s really aggravating when a product doesn’t work, 
we understand, but it will get fixed.  We go to a lot of  trouble to 
make products reliable, and the failure rate of  our amplifiers is very 
low.  This is small comfort to the few, but take it easy and give us a 
call if  you have problems.

People are interested in how long it takes for these amplifiers to 
break in. Depending on the resolution of  the rest of  your audio 
chain, you may or may not notice any break in of  the XA100 beyond 
the first 50 hours of  operation. You will likely notice the difference 
in sonic character between cold and normal operating temperature, 
so we recommend letting these amplifiers warm up before any 
serious listening. 

It takes about an hour for them to warm up, and this is where we 
adjust them first.  Then we adjust them again and again over a 
couple of  days, keeping the bias and offset in the sweet spot.  Our 
environment is about 23 degrees Centigrade, room temperature, and 
the heat sinks will rise to about 25 degrees C. above that, for a heat 
sink temperature of  about 48 degrees C.  This is where they operate 
best.

In your setup the heatsink temperature may vary a bit due to line 
voltage and ventilation, but it is not a big deal.  You should be able to 
put your hands on the heat sinks without discomfort for 10 seconds 
or so. 

The amplifier has a thermal cutout that will disconnect AC power if  
the temperature exceeds 75 degrees Centigrade.  This thermal cutout 
should never occur in real life.

You are ready to play music

Summary of Contents for XA100

Page 1: ...1 XA100 Owner s Manual pass TM XA100 Owner s Manual May 18 2006 ...

Page 2: ...that we descriptively characterize as being Single ended Class A This new topology combines the very best characteristics of Pass Laboratories X series amplifiers and the highly rated Pass Laboratories Aleph The XA series is the marriage of a highly refined Aleph output stage with the patented Supersymmetry X front end The emphasis of the XA series is to accentuate performance over power The XA se...

Page 3: ...he XA100 accommodates both single ended RCA and balanced inputs XLR Input impedance s are 11 kohm unbalanced and 22 kohm balanced to permit integration with the widest possible range of upstream components You can position this amplifier anywhere you wish but it must have ventilation We do not recommend placing it in enclosed cabinets or small closets without means for air to circulate freely Stac...

Page 4: ...le circuit breaker does away with the need for disposable fuses The frequency rating of the AC line source is 50 to 60 Hz in all cases Please verify that the amplifiers indicated voltage requirements are consistent with the supplied voltage and current at your location Transformers are input voltage specific and their change is not a trivial matter Looking at the rear panel you will see the AC pow...

Page 5: ...eaker terminal is where this voltage reference might be found On complementary designs which would be typical of all power amps produced by Pass Laboratories this is an incorrect and unsafe assumption On all Pass Laboratories power amplifiers a reference of 0 volts will be found only at pin 1 of the XLR input or at the shell of the RCA input Reference connections for these devices require special ...

Page 6: ... and give us a call if you have problems People are interested in how long it takes for these amplifiers to break in Depending on the resolution of the rest of your audio chain you may or may not notice any break in of the XA100 beyond the first 50 hours of operation You will likely notice the difference in sonic character between cold and normal operating temperature so we recommend letting these...

Page 7: ...r cables which is that they should cost less than the amplifier and contain at least some conductive material We have tried a lot of products and most work well but as a practical matter we cannot make blanket recommendations The amplifier is not sensitive to source interconnects It is also not sensitive to radio frequency pickup which allows some flexibility in choosing source interconnects witho...

Page 8: ... amps RC filtering is used to passively remove ripple from the supply rails All the power transistors in the product are hyper matched parts with gate voltages matched to 0 5 and all devices taken from the same manufacturing lot codes made on the same wafer So how long will this hardware last It is our experience that barring abuse or the odd failure of a component the first things to go will be t...

Page 9: ...al Slew rate plus minus 50 V uS Output Noise 300 uV unweighted 20 20 kHz Balanced CMRR approx 60 dB 1 kHz DC offset 100 mv Power Consumption approx 300 watts Temperature 25 degrees C above ambient at idle Dimensions 19 W x 9 H x 22 D Shipping Weight 68 lbs For more information please contact Pass Laboratories Inc P O Box 219 24449 Foresthill Rd Foresthill CA 95631 Tel 530 367 3690 Fax 530 369 2193...

Page 10: ... of origin for warrantee service Foreign distributors are only required to offer warranty service on Pass Laboratories product that they have imported Please note Conditions of warranty service and customer rights for product purchased outside the United States may vary depending upon the distribu tor and local laws Please check with your local distributor for specific rights and details Any modif...

Page 11: ... one that is fully safety rated by the necessary local authority Power Cord Protection Power supply cords should be routed so that they are not likely to be walked on abraded or pinched by items placed on or against them paying particular attention to cords where they enter plugs or exit from a device Never under any circumstance insert a cut or damaged power cord into a mains power socket Power a...

Page 12: ...speakers putting Pass Laboratories X amplifiers on the bottom for power and control conjoined with Alephs on the top for that smooth warm midrange and top end We well appreciate these complementary differences and for the past few years Pass Laborato ries has been at work marrying these two design concepts into a single amplifier topology The trick was to create an amplifier which carries the best...

Page 13: ...d for preamplifier circuits high quality amplifier front ends and other very low power output stages US Patent 5 710 522 describes the single ended Class A power ampli fier biased by a constant DC current source which negatively ghosts the speaker load with simple but effective current modulation If you have followed developments in audio for the last 10 years you know this design as the Pass Labo...

Page 14: ...ve ambient temperature so that actual chip temperatures are about 70 degrees below their rating The output devices are designed to last a very long time under these conditions with a probable life of about 50 000 hours The power supply of the XA 200 uses elaborate RF filtering and noise sup pression designed to block AC noise and line DC The substantial toroidal power transformer is followed by hi...

Reviews: