Looking at the rear panel you will see the IEC 320 AC power cord 
receptacle, a mains power switch, two pairs of  output connectors, a 
pair of  binding post connectors for remote turn-on, two RCA input 
connector and two XLR balanced input connectors.

Make sure that the mains power switch is off  (down).  Plug the AC 
cord into the back of  the amplifier, and then into the wall.  Then turn 
the breaker switch on (up).  The lights in your house may blink when 
the power supply charges the capacitors; this is normal. This mains 
power switch is not to be used as a safety disconnect during servicing 
and is not a substitute for unplugging the power cord.

On the front panel, the “Standby” LED indicator should be glowing 
blue, indicating that the power is on.  The “Power” LED should not 
be on.  If  the “Power” LED is on, don’t get excited, just use the front 
panel stand-by button to go into stand-by mode, with the “Standby” 
LED on and the “Power “ LED off.

OK, so the amplifier is sitting there in stand-by mode with just the 
single blue LED lit.  No speaker connected, as yet.  You can go ahead 
and connect the source and speakers.  Some speaker cables are very 
difficult to work with due to physical size and construction, make sure 
the speaker connections do not short together.  It is recommended 
that you connect the speaker ends of  these cables first.

Some powered subwoofers require an audio signal ground reference 
and their makers may suggest that a black speaker terminal is where 
this  voltage  reference  might  be  found.  On  complementary  designs, 
which would be typical of  all power amps produced by Pass Laborato-
ries™, this is an incorrect and unsafe assumption.  On all Pass Labo-
ratories™ power amplifiers a reference of  0 volts will be found only at 
pin 1 of  the XLR input or at the shell of  the RCA input. 

Reference connections for these devices require special consideration 
when used with our product.  If  you have such a device, and wish to 
use it with our product, please contact our Foresthill, California fac-
tory for specific instructions.... you have been warned.

The amplifier can be driven single-end or balanced, if  driving the am-
plifier single-ended, leave the supplied jumper in place (between pins 
1 & 3 on the XLR).  Your amplifier will operate without the jumper in 
place, but performance will be significantly diminished.
 
Now that the source component is connected, make sure there is no 
signal  coming  from  it,  probably  by  turning  the  volume  all  the  way 
down. With the speakers connected, push the front panel button to 
activate the amplifier.  The “Power” LED will come on.

Summary of Contents for X150.5

Page 1: ...1 X150 5 Owners Manual pass TM X150 5 Owner s Manual May 17 2006 ...

Page 2: ...tion be tween the two halves of the balanced circuit that further perfects this match Any distortion and noise not already identical to the two halves is made more identical by a factor of about 10 and the result is improved noise cancellation at the output of the amplifier Unlike feedback techniques where the goal is to correct for the distortion by feeding a gain stage an inversely distorted sig...

Page 3: ...e to explosive transient and back to silence without a trace and without information loss Very unlike conventional high power amplifiers they provide this level of power with a subtlety befitting some of the better tube amplifiers This per formance is consistence across the audio spectrum and the amplifiers are unconditionally stable into all speaker loads So relax and enjoy your amplifier Call us...

Page 4: ... 2 amp type 3AG 250V slow blow and for units rated at either 100 or 120 volts the fuse will be a 5 amp type 3AG slow blow Do not substitute other types voltage amperage or time constant fuses for the specified replacement The frequency rating of the AC line source in all instances will be 50 to 60 Hz Please verify that the amplifiers indicated voltage requirements are consistent with the line volt...

Page 5: ...sical size and construction make sure the speaker connections do not short together It is recommended that you connect the speaker ends of these cables first Some powered subwoofers require an audio signal ground reference and their makers may suggest that a black speaker terminal is where this voltage reference might be found On complementary designs which would be typical of all power amps produ...

Page 6: ...the heat sinks will rise approximately 25 degrees C above that for an average on heat sink temperature of 48 degrees C Sonically they are at their best when the heatsinks are approximately 50 degrees C In your setup the temperature may vary a bit due to line voltage varia tions and ventilation but this is not a big deal You should be able to put your hands on the heat sinks without discomfort for ...

Page 7: ...ace In these cases take special care that the source does not contain a differential DC component and confirm the differential DC offset of the pre amplifier is sufficiently low This differential voltage is easily adjusted by a qualified technician armed with the appropriate service documents We have a general recommendation about interconnects which is that they should cost less than the amplifie...

Page 8: ...rience they will last 15 to 20 years before needing replacement Fortunately these components die gracefully typically with years of warning and are easily replaced After that the longevity will depend on the number of operating ther mal cycles but we can attest to having had amplifiers operating in the field in excess of 20 years with no particular mortality except capaci tors We don t have good i...

Page 9: ...300 uV unweighted 20 20 kHz Balanced CMRR 60 dB 1 kHz input common mode rejection ratio DC offset 100 mv differential Power Consumption 250 watts idle 600 watts maximum Temperature 25 degrees C above ambient at idle Dimensions 19 W x 22 D x 7 5 H Shipping Weight 68 lbs For more information please contact Pass Laboratories Inc P O Box 219 24449 Foresthill Rd Foresthill CA 95631 Tel 530 367 3690 Fax...

Page 10: ... of origin for warrantee service Foreign distributors are only required to offer warranty service on Pass Laboratories product that they have imported Please note Conditions of warranty service and customer rights for product purchased outside the United States may vary depending upon the distribu tor and local laws Please check with your local distributor for specific rights and details Any modif...

Page 11: ... that they are not likely to be walked on abraded or pinched by items placed on or against them paying particular attention to cords where they enter plugs or exit from a device Never under any circumstance insert a cut or damaged power cord into a mains power socket Power and Signal Cables should never be connected disconnected with equipment powered up Failure to heed this warning may damage or ...