Water and moisture:  

Electrical devices should not be used near water ( 

as per example, near a bathtub, washbasin, kitchen sink, laundry tub, wet 
basement or swimming pool ).  Care should be taken such that objects 
do not have the opportunity to fall, and that liquid is never spilled onto or 
into the device enclosure through openings.

Power Sources:  

An electrical device must  be connected to a mains 

power source in strict accordance with the supplied  product owner’s 
manual.  Please verify that the AC mains voltage specified in the product 
manual matches those requirements indicated on the unit and the AC 
voltage provided to your location by the power company.

Grounding:  

Adequate precautions should be taken so that the 

grounding provisions built into an electrical product are never defeated.

Power Cords:  

Pass Laboratories provides a power supply cord that 

meets all legislated requirements for the market in which the product was 
originally sold.  If you choose to substitute an after-market product we 
urge you to choose one that is fully safety rated by the necessary local 
authority.

Power Cord Protection:  

Power supply cords should be routed so that 

they are not likely to be walked on, abraded, or pinched by items placed 
on or against them, paying particular attention to cords where they enter 
plugs or exit from a device.  Never under any circumstance insert a cut or 
damaged power cord into a mains power socket.

Power and Signal:  

Cables should never be connected / disconnected 

with equipment powered up.  Failure to heed this warning may damage or 
destroy equipment.

Ventilation:  

Power-amplifiers run hot, but you should be able to place 

your hands on them without discomfort.  You must allow for this heat 
in installation, by providing for free air circulation around the product.  
Electronics should not be subjected to sources of excessive radiant heat. 
Excessive heat can shorten the life of the product and may cause the 
electronics to self-protect and shut down.

Servicing:  

To reduce the risk of fire, electrical shock or other injuries, 

the user should not attempt to service the device beyond that which 
is described in the operating instructions.  All other servicing must be 
referred to qualified service personnel.

For Units With Externally Accessible Fuse Receptacle: 

Unplug 

the device from all sources of power before changing  or inspecting any 
fuse.  Replace fuse with one of same physical size, type and rating as that 
specified by the manufacturer for that product.

For your protection please 

read the following:

Summary of Contents for X150.5

Page 1: ...1 X150 5 Owners Manual pass TM X150 5 Owner s Manual May 17 2006 ...

Page 2: ...tion be tween the two halves of the balanced circuit that further perfects this match Any distortion and noise not already identical to the two halves is made more identical by a factor of about 10 and the result is improved noise cancellation at the output of the amplifier Unlike feedback techniques where the goal is to correct for the distortion by feeding a gain stage an inversely distorted sig...

Page 3: ...e to explosive transient and back to silence without a trace and without information loss Very unlike conventional high power amplifiers they provide this level of power with a subtlety befitting some of the better tube amplifiers This per formance is consistence across the audio spectrum and the amplifiers are unconditionally stable into all speaker loads So relax and enjoy your amplifier Call us...

Page 4: ... 2 amp type 3AG 250V slow blow and for units rated at either 100 or 120 volts the fuse will be a 5 amp type 3AG slow blow Do not substitute other types voltage amperage or time constant fuses for the specified replacement The frequency rating of the AC line source in all instances will be 50 to 60 Hz Please verify that the amplifiers indicated voltage requirements are consistent with the line volt...

Page 5: ...sical size and construction make sure the speaker connections do not short together It is recommended that you connect the speaker ends of these cables first Some powered subwoofers require an audio signal ground reference and their makers may suggest that a black speaker terminal is where this voltage reference might be found On complementary designs which would be typical of all power amps produ...

Page 6: ...the heat sinks will rise approximately 25 degrees C above that for an average on heat sink temperature of 48 degrees C Sonically they are at their best when the heatsinks are approximately 50 degrees C In your setup the temperature may vary a bit due to line voltage varia tions and ventilation but this is not a big deal You should be able to put your hands on the heat sinks without discomfort for ...

Page 7: ...ace In these cases take special care that the source does not contain a differential DC component and confirm the differential DC offset of the pre amplifier is sufficiently low This differential voltage is easily adjusted by a qualified technician armed with the appropriate service documents We have a general recommendation about interconnects which is that they should cost less than the amplifie...

Page 8: ...rience they will last 15 to 20 years before needing replacement Fortunately these components die gracefully typically with years of warning and are easily replaced After that the longevity will depend on the number of operating ther mal cycles but we can attest to having had amplifiers operating in the field in excess of 20 years with no particular mortality except capaci tors We don t have good i...

Page 9: ...300 uV unweighted 20 20 kHz Balanced CMRR 60 dB 1 kHz input common mode rejection ratio DC offset 100 mv differential Power Consumption 250 watts idle 600 watts maximum Temperature 25 degrees C above ambient at idle Dimensions 19 W x 22 D x 7 5 H Shipping Weight 68 lbs For more information please contact Pass Laboratories Inc P O Box 219 24449 Foresthill Rd Foresthill CA 95631 Tel 530 367 3690 Fax...

Page 10: ... of origin for warrantee service Foreign distributors are only required to offer warranty service on Pass Laboratories product that they have imported Please note Conditions of warranty service and customer rights for product purchased outside the United States may vary depending upon the distribu tor and local laws Please check with your local distributor for specific rights and details Any modif...

Page 11: ... that they are not likely to be walked on abraded or pinched by items placed on or against them paying particular attention to cords where they enter plugs or exit from a device Never under any circumstance insert a cut or damaged power cord into a mains power socket Power and Signal Cables should never be connected disconnected with equipment powered up Failure to heed this warning may damage or ...