The amplifier has only the two stages, an input stage of a balanced pair of 

input devices, and the output stage, a balanced pair of single-ended Class 

A power Mosfets.  Like the Aleph™, you can trace a path from input to 

output through only two gain devices.  Like the X amps, feedback is used 

only to set the gain and correct for dissimilarities between the two matched 

output stages.  

There are no adjustments.  There are no frequency compensation capaci-

tors.  The amplifiers are unconditionally stable and reliable into any load.  

They are not fragile, temperamental or prone to failure.

The XA amplifiers operate at approximately 33% efficiency, which is to 

say they idle at three times their rated output.  The XA200 is rated at 200 

watts output into 8 ohms and draws something over 600 watts of AC 

power. This design is an exercise in highly conservative engineering, which 

provides exceptional reliability and product longevity.  The output devices 

are exposed to no more than a fraction of the voltage and wattage they are 

designed to endure.

 

These rugged power devices are matched to about .3% and mounted on 

Mica insulators.  Their massive heat sinks run at about 25 degrees C. above 

ambient temperature, so that actual chip temperatures are about 70 degrees 

below their rating.  The output devices are designed to last a very long time 

under these conditions, with a probable life of about 50,000 hours.

The power supply of the XA 200 uses elaborate RF filtering and noise sup-

pression designed to block AC noise and line DC.  The substantial toroidal 

power transformer is followed by high speed rectifiers, and significant uF 

of computer grade capacitors in a passive filter arrangement.  In addition 

to a main power switch the amplifier has a standby mode, which shuts 

down the bias to the circuit while keeping the supply active, significantly 

extending the life of the filter capacitors.

The sound of the XA amplifiers is a quantum leap over the parents.  They 

retain the sweet warmth and lushness of the Aleph™ series without the 

fluffy coloration’s.  The dynamic contrast is even better than the X series; 

transients leaping from black to crescendo and back again with no tele-

graphing or hangover.

The bass has as much control over the speaker as the original X amps, but 

is a bit more neutral and carries subtler nuance.  The midrange is a little 

deeper and the soundstage wider than the Alephs™.

Are the XA’s better than Alephs™ and X’s in every respect? 

Yes, except for the higher power/current ratings of the X amps.

Are they the best audio amplifiers that money can buy? Absolutely!

Summary of Contents for XA60

Page 1: ...1 XA60 Owner s Manual pass TM XA60 Owner s Manual May 18 2006 ...

Page 2: ...rcuit topology that we descriptively characterize as being Single ended Class A This new topology combines the very best characteristics of Pass Laboratories X series amplifiers and the highly rated Pass Laboratories Aleph The XA series is the marriage of a highly refined Aleph output stage with the patented Supersymmetry X front end The emphasis of the XA series is to accentuate performance and s...

Page 3: ...le into any load presented by a loudspeaker but will provide less power into other than 8 ohms The XA60 accommodates both single ended RCA and balanced inputs XLR Input impedance s are 11 kohm unbalanced and 22 kohm balanced to permit integration with the widest possible range of upstream components You can position this amplifier anywhere you wish but it must have ventilation We do not recommend ...

Page 4: ...ar panel It will be either 240 volts 220 volts 120 volts or 100 volts all units protected by a type 3 AG slow blow fuse of the appropriate ampacity The operational voltage is not user changeable Transformers are input voltage specific and their change is not a trivial matter The frequency rating of the AC line source is 50 to 60 Hz in all cases Please verify that the amplifiers indicated voltage r...

Page 5: ...se Some powered subwoofers require an audio signal ground reference and their makers may suggest that a black speaker terminal is where this voltage reference might be found On complementary designs which would be typical of all power amps produced by Pass Laboratories this is an incorrect and unsafe assumption On all Pass Laboratories power amplifiers a reference of 0 volts will be found only at ...

Page 6: ...product is very low This is small comfort to the few but take it easy and give us a call if you have problems People are interested in how long it takes for these amplifiers to break in Depending on the resolution of the rest of your audio chain you may or may not notice any break in of the XA60 beyond the first 50 hours of operation You will likely notice the difference in sonic character between...

Page 7: ...lightly less distortion at a given voltage current level than resistive loads The XA circuit was designed to be quite happy driving electrostatic speakers and any other esoteric loads we know of We have a general recommendation about interconnects and speaker cables which is that they should cost less than the amplifier and contain at least some conductive material We have tried a lot of products ...

Page 8: ...supply filter capacitors These caps are used to create the unregulated output stage rails RC filtering is used to passively remove ripple from the supply rails All the power transistors in the product are hyper matched parts with gate voltages matched to 0 5 and all devices taken from the same manufacturing lot codes made on the same wafer So how long will this hardware last It is our experience t...

Page 9: ...l Slew rate plus minus 50 V uS Output Noise 300 uV unweighted 20 20 kHz Balanced CMRR approx 60 dB 1 kHz DC offset 100 mv Power Consumption approx 300 watts Temperature 25 degrees C above ambient at idle Dimensions 19 W x 7 H x 20 D Shipping Weight 68 lbs For more information please contact Pass Laboratories Inc P O Box 219 24449 Foresthill Rd Foresthill CA 95631 Tel 530 367 3690 Fax 530 369 2193 ...

Page 10: ... of origin for warrantee service Foreign distributors are only required to offer warranty service on Pass Laboratories product that they have imported Please note Conditions of warranty service and customer rights for product purchased outside the United States may vary depending upon the distribu tor and local laws Please check with your local distributor for specific rights and details Any modif...

Page 11: ... one that is fully safety rated by the necessary local authority Power Cord Protection Power supply cords should be routed so that they are not likely to be walked on abraded or pinched by items placed on or against them paying particular attention to cords where they enter plugs or exit from a device Never under any circumstance insert a cut or damaged power cord into a mains power socket Power a...

Page 12: ...speakers putting Pass Laboratories X amplifiers on the bottom for power and control conjoined with Alephs on the top for that smooth warm midrange and top end We well appreciate these complementary differences and for the past few years Pass Laborato ries has been at work marrying these two design concepts into a single amplifier topology The trick was to create an amplifier which carries the best...

Page 13: ...d for preamplifier circuits high quality amplifier front ends and other very low power output stages US Patent 5 710 522 describes the single ended Class A power ampli fier biased by a constant DC current source which negatively ghosts the speaker load with simple but effective current modulation If you have followed developments in audio for the last 10 years you know this design as the Pass Labo...

Page 14: ...ve ambient temperature so that actual chip temperatures are about 70 degrees below their rating The output devices are designed to last a very long time under these conditions with a probable life of about 50 000 hours The power supply of the XA 200 uses elaborate RF filtering and noise sup pression designed to block AC noise and line DC The substantial toroidal power transformer is followed by hi...