8.1 CONFIGURATION OF THE SYSTEM
Configuration activities may be carried out only by qualified personnel, suitably trained for this purpose.
A) Password
rom the MUSIC MENU, go to the MAIN MENU and select <
CONFIGURATION
>. If access only with a password is
enabled, ‘Enter configuration password’ will appear on the screen.
B) Muting the BEEP
During the initialisation process, it is possible that faults may be detected due to differences between the configuration of
the system being connected and the values set by default. To mute the acoustic signal (beep) temporarily, browse down
through the CONFIGURATION menu and select the item ‘Beep operation’.
C) Acquisition of impedances
From the CONFIGURATION menu, select the item ‘
set> IMP. REFERENCE
’ to access the ‘
Zone reference setting
’
screen page.
From here it is possible to set the reference impedance and the tolerance for controlling the impedance of the loudspeaker
lines (refer to the point on
Acquisition of impedance and setting of tolerance
on page 35).
In the ‘
Beep operation setting
’ window, move the ‘Beep enable’ slider to ‘Off’.
Press ‘Save’ to save this setting.
!
N.B.
In order to comply with regulations, before returning the equipment to its normal operation it is necessary to
enable the acoustic signalling by returning the ‘Beep enable’ slider to its ‘On’ position.
Enter the 4-digit code of the password and confirm by pressing ‘
Enter
’ (the factory default password is
3333
; see page 34).