• Setting the address of the P8136
Master Unit
To enter the programming mode, press keys
A
and
B
at the same time. LED
F
will start to flash while the other LEDS indicate the current address of
the master unit. If they are all extinguished this means that the current address is that of the “pilot”
master, that is to say
0
.
To change your selection press the key corresponding to the desired address; to select address
0
press the key corresponding to the illuminated LED.
Press
F
to confirm your selection.
Address
0
Address
1
Address
2
Address
3
Address
4
Address
5
Fig. A9
2. SLAVE FUNCTIONS
(PROGRAM INSERTION keypad)
Fig. A10
• Address of
slave unit within the P8136 master unit
The address of the Slave Unit is factory set at 0. This address MUST NOT BE OTHER THAN NOUGHT under any circumstances.
It is, however, possible to check the factory setting and to correct it, if necessary:
To enter the programming mode, press keys
1
and
2
at the same time. LED
6
will start to flash.
If all the LEDs (from
1
to
5
) are extinguished, the address is
0
(
correct
). If any of the LEDs are illuminated, press the relevant keys to unselect them.
Press key
6
to confirm your choice.
Address
0
Fig. A11
• Group
To enter the programming mode, press keys
1
and
5
at the same time. LED
6
will start to flash.
Press the key corresponding to the number you wish to associate with the group (from
1
to
5
:
key 1
>
group 1
;
key 2
>
group 2
and so on).
To select group
0
, press the key corresponding to the illuminated LED so as to extinguish LEDs
1
to
5
.
Press key
6
to confirm your choice.
Section