MAINTENANCE

Paslode

®

 tools are built for ease of maintenance.  A few 

simple details will assure trouble-free operation and long 

tool life. Anyone who uses or maintains the tool must read 

the safety and maintenance instructions.  Study the sche-

matic drawing before starting any repairs on the tool.

Air-operated tools must be inspected periodically, and worn 

or broken parts must be replaced to keep the tool operating 

safely and ef

fi

ciently.  Also the items on the maintenance 

chart must be checked often.

Cold Weather Care

When temperatures are below freezing, tools should be 

kept warm by any convenient, safe method.  If this is not 

possible, the following procedure should be used to warm 

up the tools.

Reduce the regulated air pressure to 30 psi

 (2 Bar)

.

Remove all fasteners from the tool.

Collect an air line and blank 

fi

re the tool. The reduced

air pressure will be enough to free-

fi

re the tool. Slow speed

operation tends to warm up the moving parts. Slowing up

the piston helps the bumper and the O-rings to become

springy.

Once the tool is warmed up, readjust the regulator to

the proper working pressure and reload the tool.

Open the drain on the air compressor tank to drain any

moisture at least daily in extremely cold or humid weather.

A few ounces of anti-freeze in the tank will keep the air

free of frost.

Testing the Tool After Servicing

After replacing any part or parts, it is important to check 

the tool for proper operation.  This ensures that the tool 

was put together correctly, is safe to use, and will perform 

the job properly.

Ensure that all hardware is tight.

Ensure that the work contacting element is installed

correctly in relation to the trigger, and that both parts move

freely.

Ensure that the magazine is properly attached.

Ensure that the required safety information on the tool

is legible.

Use only Paslode approved fasteners in the tool, and

ensure that they are correct for the application.

Ensure that a male air 

fi

tting is securely connected to

the tool.

Test the tool by driving fasteners into a workpiece iden-

tical to the tool's application.

Check the tool for air leaks during testing and for the

proper sequence of operation.

Ensure that all fasteners are driven to the same depth

and that the crown of the fastener is 

fl

ush with the work-

piece.

  

Most minor problems can be resolved quickly and easily

using the maintenance table that follows. If problems per-

sist, contact your Paslode dealer for assistance.

Summary of Contents for C Series

Page 1: ...IMPORTANT DO NOT DESTROY It is the customerʼs responsibility to have all operators and service personnel read and understand this manual OPERATING MANUAL AND TOOL SCHEMATIC P Part No B20118 219495 1 08 17 PRINTED IN TAIWAN 2017 Illinois Tool Works Inc ...

Page 2: ...part or accessorywhich provesto be defectivewithin the specific time period Any replacement part or accessory provided in accordance with this warranty will carry a warranty for the balance of the period of warranty applicable to the part it replaces This warranty does not apply to part replacement required due to normal wear This warranty is void as to any tool whichhas been subjected to misuse a...

Page 3: ...N P T male plug The inside diameter should be 28 7mm or larger The fitting must be capable of discharging tool air pressure when disconnected from the air supply OPERATING AIR PRESSURE 80 to 120 p s i 5 5 to 8 3 bars Select the operating air pressure within this range for best tool performance DO NOT EXCEED THIS RECOMMENDED OPERATING PRESSURE NAIL LENGTH 1 2 PP PP SHANK DIAMETER 16 gauge 1 6 mm TO...

Page 4: ...s equipped with a safety mechanism called a work contacting element to help prevent accidental firing Never tamper with disable or remove the work contacting element Do not use the tool unless the work contacting element is working properly The tool could fire unexpectedly DISCONNECT THE TOOL WHEN NOT IN USE Always disconnect the tool from the air line when it is not in use when you leave the work a...

Page 5: ...ide Pivot front guide forward 3 Clear jam and push driver blade back up to its normal position 4 Close front guide and latch it Check that work contacting element moves freely TOOL OPERATION Fasteners The Paslode T250 16S Finish Nailer drives Paslode 16 gauge fasteners designed to be used with the tool The use of fasteners that do not meet Paslode standards could cause tool damage and will void al...

Page 6: ...r to avoid unintentional fastener discharge 6 Reversible Belt Hook The belt hook can be changed from the left hand side of the tool to the right hand side To change the position squeeze the base of the belt hook and remove it from the tool and tool and position it on the desired side Sequential Operation The sequential setting T prevents succesive or bounce driving Depress the work contacting elem...

Page 7: ...he tool Open the drain on the air compressor tank to drain any moisture at least daily in extremely cold or humid weather A few ounces of anti freeze in the tank will keep the air free of frost Testing the Tool After Servicing After replacing any part or parts it is important to check the tool for proper operation This ensures that the tool was put together correctly is safe to use and will perfor...

Page 8: ...Prevent accumulation of moisture and dirt Prevent clogging of filter with dirt Prevent air leakage and pro mote efficient operation Promote operator safety and efficient tool operation Prevent jamming of fasteners Keep tool operating efficiently and maintain Paslode tool warranty Open manual petcock most air supply systems have such a valve Wash with soap and water or follow manufacturers instruc ...

Page 9: ...arger air lines 3 8 inch 10mm ID minimum Adjust the depth of drive adjustment extend length Reduce air pressure Open front guide latch release jammed fastener and close latch securely Check magazine for proper fasteners Magazine follower should slide freely Clean as needed to remove debris Make sure correct fasteners are being used Use fasteners that meet Paslode specifications only Increase air f...

Page 10: ......

Page 11: ......

Page 12: ...P ITW Construction Asia pacific 47 55 Williamson Road Ingleburn NSW 2565 Paslode New Zealand 8 Orbit Drive Albany Auckland 2017 Illinois Tool Works Inc 12 ...

Reviews: