MANUALE UTENTE
,
USO E MANUTENZIONE
39
In the Insert or Stella model: slide the insert all the way forward, remove the cap
on the side protection (figure 19) then unscrew the underlying cap fixed with bolts
(figure 19a), the side on which to intervene corresponds to that of the smoke
extractor.
(figura 19
)
Disassembling, therefore, these caps, it will be possible to access the tube facia (7
vertical tubes) you will have to use a brush or tube long enough to reach the entire
length of the tubes, then remove any residues, sucking everything. After having
carried out all the cleaning operations, reassemble the caps with the relative
gaskets, if worn replace them.
However, for the first few times, it is recommended to have the complete cleaning
carried out by a specialized technician.
Position of smoke outlet and inspection cap: flue outlet side
N. of pipes in the tube bundle: 7
In the Otello model, disassemble the top cover (figure 20) and remove the majolicas, then
unscrew the underlying cap fixed with bolts (figure 20a), the side on which to intervene
corresponds to that of the smoke extractor (figure 20 b).
(figura 20 )
(figura 20b )
(figura 19
a)
Summary of Contents for Otello