USER MANUAL
ANOMALY
CAUSE
REMEDIES
Failure to stop the
air fan.
Faulty fan.
control or replace fan
room probe is faulty
control or replace probe
The product has not yet reached
the shutdown temperature.
Attendere.
faulty electronic board
Replace electronic board
The remote control
does not work
Remote control battery low
replace battery
remote control is faulty
replace remote control
After the ignition
phase, the stove
immediately goes into
the "waiting for
cooling" phase
External room thermostat discharged
or set with low temperature
Set the temperature again and
replace the batteries
Room probe is faulty
Check probe operation and replace
if necessary, check the set temp.
termperature set is low
Increase set temperature
The sufa does
not ignite or pass
in
"WORK"
electric black out
Check that the electrical outlet is
plugged in and that the system is
working
Smoke probe in block
Check and replace the probe if
necessary
Fuse tripped following a fault
replace fuse
Clogged exhaust or smoke duct
Clean the smoke outlet and /
or the smoke duct.
Badly positioned brazier
Check and reposition the brake
correctly in its seat.
electrical resistance fuelty
replace resistance
stove in “hot fumi”
stove or chamney dirty
clean the stove and the smoke
outlet
faulty probe or board
clean or replace probe or board
check probe position
43
Summary of Contents for Lia
Page 1: ...Produzione stufe e termostufe a pellets e policombustibili User Manual Lia...
Page 2: ......
Page 16: ...14 figura13 figura14...
Page 24: ...user manual 22...
Page 25: ...user manual 23...
Page 26: ...user manual 24...
Page 27: ...user manual 25...
Page 29: ...user manual 27...
Page 32: ...user manual 30...
Page 36: ...user manual 34...
Page 37: ...Black Out a timing user manual 35...
Page 38: ...user manual 36...
Page 39: ...user manual 37...
Page 49: ...MANUALE UTENTE USO E MANUTENZIONE CERTIFICAZIONE AMBIENTALE 4 STELLE 47...