Paser Firewall OBD2 Installation Manual Download Page 2

Release date: 09.12.17   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

rev 1.0 17 

2 / 4 

 

 

FIREWALL 

INSTALLATION MANUAL

 

30 m 

DIAGRAM 1 code CF0044UNUN61              FIRWALL CONNECTIONS WITH REMOTE CONTROL (STAND ALONE MODE) 

1. Please identify the location of the original vehicle 

OBD2 port (www.paser.it/firewall/location) and 
then remove the connector from its housing; 

2. Please connect the male OBD2 plug to the original 

OBD2 socket (1); 

3. Connect to a wire ignition  
4. Please connect the Firewall OBD2 module to multi-

way connectors of the OBD2 harness of the kit;  

5. Please connect the harness OBD2 socket of the kit 

in the same place where it was connected to the 
OEM plug. 

INCLUDED 

HOW IT WORKS? 

The unit supplied with remote control follows this procedure for the activation / deactivation of Firewall. The remote control has 2 
buttons, please refer to the diagram below: 

BUTTON  PRESS 

FIREWALL STATUS

 

OBD2 READING

 

 BUZZER 

FIREWALL LED 

 

A 1 

OFF

 

POSSIBLE

 

2 BEEP 

GREEN

 

B 2 

ON

 

NOT POSSIBLE

 

1 BEEP 

RED

 

Warning! 
When Firewall is off (OFF) you can set it so that every turning on of the ignition, the unit emits 5 beeps: this setting allows the user 
to know when OBD protection is OFF. 
To set this mode, please connect the BLACK wire to an ignition positive. 

HOW IT WORKS? 

The version supplied as ignition configuration, it’s a stand alone module and allows the Firewall OBD2 managing by a sequence of 3 consecutive car ignition 
activations. The procedure is the following: 

 

 

 

 

 

 
Warning! 
 
When Firewall is off (OFF) at every turning on of the ignition, the unit emits 5 beeps: this allows the user to know the OBD protection is OFF. 
Also on this setting, it is possible to combine a remote control. 

CONTROL PANEL TURNING ON 

FIREWALL

 

STATUS

 

OBD2 READING 

 

 BUZZER 

FIREWALL LED 

 

OFF

 

POSSIBLE

 

2 BEEPS 

GREEN

 

ON

 

NOT POSSIBLE

 

1 BEEP 

RED

 

DIAGRAM 2 code CF0044UNUN41                  FIREWALL CONNECTION WITH VEHICLE KEY (STAND ALONE ON / OFF MODE)  

1. Please identify the location of the original vehicle 

OBD2 port (www.paser.it/firewall/location) and 
then remove the connector from its housing; 

2. Please connect the male OBD2 plug to the original 

OBD2 socket (1); 

3. Connect to a wire ignition  
4. Please connect the Firewall OBD2 module to multi-

way connectors of the OBD2 harness of the kit;  

5. Please connect the harness OBD2 socket of the kit 

in the same place where it was connected to the 
OEM plug. 

FIREWALL OBD2 

SOCKET 

INSTALLATION 

INSTALLATION 

FIREWALL OBD2 

SOCKET 

Summary of Contents for Firewall OBD2

Page 1: ...d in default kit you need 1 Plug and Play harness please see compatibility codes on the site www paser it firewall 1 two channels remote control in stand alone mode with remote control DEFAULT SETTING Firewall has different working modes Default kit is set as stand alone controlled by remote control not supplied or wire Default kit has the wire input BLACK wire set to GND polarity this means that ...

Page 2: ...r to know when OBD protection is OFF To set this mode please connect the BLACK wire to an ignition positive HOW IT WORKS The version supplied as ignition configuration it s a stand alone module and allows the Firewall OBD2 managing by a sequence of 3 consecutive car ignition activations The procedure is the following Warning When Firewall is off OFF at every turning on of the ignition the unit emi...

Page 3: ...CONTROL STAND ALONE MODE 1 Please identify the location of the original vehicle OBD2 port www paser it firewall location and then remove the connector from its housing 2 Please connect the male OBD2 plug to the original OBD2 socket 1 3 Connect to a wire ignition 4 Please connect the Firewall OBD2 module to multi way connectors of the OBD2 harness of the kit 5 Please connect the harness OBD2 socket...

Page 4: ...OTE CONTROL AND WIRE THORUGH REMOTE CON TROL AND WIRE WITH 3 IMPULSES 2 FLASHES ORANGE 1 FLASH RED 2 FLASHES RED ACTIVATION WIRE POLARITY GND POLARITY 12 VDC POLARITY x5 WARRANTY CONDITIONS THIS PRODUCT IS GUARANTEED 2 YEARS FOR ANY MANUFACTURING DEFECT THE WARRANTY IS VALID ONLY WITH THE PURCHASE INVOICE RESET The module can be supplied with a remote control for the activation deactivation of the...

Reviews: