H a n d - G r i p   H e a r t   R a t e   S e n s o r

Technical Support

4

012-10374B

Technical Support

Contact Technical Support for information about possible replacement parts 

and for assistance with any PASCO product: Contact PASCO at:

For more information about the Hand-Grip Heart Rate Sensor and the latest 

revision of this manual, visit the PASCO web site: www.pasco.com

Limited Warranty For a description of the product warranty, see the PASCO catalog. Copyright The 

PASCO scientific 012-10374B 

Hand-Grip Heart Rate Sensor Instruction Manual

 is copyrighted with all 

rights reserved. Permission is granted to non-profit educational institutions for reproduction of any part 

of this manual, providing the reproductions are used only in their laboratories and classrooms, and are 

not sold for profit. Reproduction under any other circumstances, without the written consent of PASCO 

scientific, is prohibited. Trademarks PASCO and PASCO scientific are trademarks or registered 

trademarks of PASCO scientific, in the United States and/or in other countries. For more information 

visit www.pasco.com/legal. 

Product End of Life Disposal Instructions:

This electronic product is subject to disposal and recycling regulations that vary 

by country and region. It is your responsibility to recycle your electronic 

equipment per your local environmental laws and regulations to ensure that it 

will be recycled in a manner that protects human health and the environment. 

To find out where you can drop off your waste equipment for recycling, please 

contact your local waste recycle/disposal service, or the place where you 

purchased the product.

The European Union WEEE (Waste Electronic and Electrical Equipment) 

symbol (to the right) and on the product or its packaging indicates that this 

product must not be disposed of in a standard waste container.

Address: PASCO scientific

10101 Foothills Blvd.

Roseville, CA 95747-7100

Phone: 916-462-8384 (worldwide)

800-772-8700 (U.S.)

Web:

www.pasco.com

Email:

[email protected]

Summary of Contents for PAS Port PS-2186

Page 1: ...eeded PASCO Interface See the PASCO Catalog for details PASCO Data Collection Software See the PASCO Catalog for details For Educational Use Only Note This is not a medical device It is designed for educational use only and should not be used in any medical process such as life support or patient diagnosis It is also not intended for use in graduate research or industry including industrial contro...

Page 2: ...t Rate Sensor is from 40 to 240 beats per minute Theory of Operation Like an electrocardiograph EKG that monitors the electrical signal of the heart the Hand Grip Heart Rate Sensor measures electrical signals that start at the heart and reach the skin at the palms of the hands The sensor box has a yellow light emitting diode LED that indicates when the sensor is in STANDBY mode and a green LED tha...

Page 3: ...with the sample rate left at the default of one sample per five seconds 4 Click or press Stop to end data collection Measurement Technique When you are using the Hand Grip Heart Rate Sensor grasp the hand grips firmly but not too tightly in the palms of the hands so that one of the metallic sides of each grip is in the center of the palm Measurements will be easier and more accurate if the hands a...

Page 4: ...rademarks PASCO and PASCO scientific are trademarks or registered trademarks of PASCO scientific in the United States and or in other countries For more information visit www pasco com legal Product End of Life Disposal Instructions This electronic product is subject to disposal and recycling regulations that vary by country and region It is your responsibility to recycle your electronic equipment...

Reviews: