www.parweld.com
66
3.0 Technical
Specifications
The XTM 201Di, is a compact type machine with integrated wire feed
unit for use with single phase 110/230V supply with smart
input switching.
Process
Feature
XTM201 Di
Input Voltage
110V +/-10% 230V +/-10%
Hz
50/60
50/60
Phases
1
1
Rated input KVA
3.7
MIG
Wire Drive
2 roll
Fuse Rating
(A)
32
16
Current Draw Max(A)
32
18.9
No-load Voltage
V
48V
48V
Rated working
Voltage V
14.5-21
14.5-24
Rated Current A
10-140
10-200
MMA
Fuse Rating
(A)
32
16
Current Draw Max(A)
28
19.8
No Load Voltage
45V
45V
Rated Working
Voltage V
20.4-24.4
20.4-28
Rated Current A
10-110
10-200
TIG
Fuse Rating
(A)
32
16
Current Draw Max(A)
25.5
19.8
No Load Voltage
45V
45V
Rated Working
Voltage V
10.4-15.6
10.4-18
Rated Current A
10-140
10-200
Duty Cycle
110V input
230V input
MIG
35%
60%
100%
25%
60%
100%
140A
115A
100A
200A
140A
105A
MMA
50%
60%
100%
25%
60%
100%
110A
95A
85A
200A
140A
105A
TIG
60%
100%
25%
60%
100%
140A
115A
200A
140A
105A
4.0 Installation
Read entire installation section before starting installation.
SAFETY PRECAUTIONS
•
ELECTRIC SHOCK can kill.
• Only qualified personnel should perform this installation.
•
Only personnel that have read and understood the Operating
Manual should install and operate this equipment.
•
Machine must be grounded per any national, local or other
applicable electrical regulations.
•
The MIG power switch is to be in the OFF position when
installing work cable and torch and when connecting other
equipment.
4.1 Location
Position the power source so that its cooling air inlets and outlets are
not obstructed.
A. 100mm (4in.) minimum
B. 100mm (4in.) minimum
4.2 Input and Grounding Connection
WARNING
Before starting the installation, check that your power supply
is adequate for the voltage, amperage, phase, and frequency
specified on the Machine nameplate.
The 110/230 volt 50 Hz machine is supplied with a 3m input cable
and without plug, ensure that you connect a plug that is suitably
rated for the power draw of the machine and the environmental
location.
Have a qualified electrician connect the input plug.
B
A