7200 Monitor Instruction Manual
The 7200 Monitor can be used with several different Partech sensors, further details of each type can be found in the
relevant instruction manual.
12.1 Select Sensor Type
The sensors that can be configured for use with the 7200 Monitor are displayed as a list, a small tick indicates the
currently selected sensor type. To select a different sensor type, use the
keys to highlight the required sensor and
press the
OK
key. A small tick will appear next to the required sensor type. Press the
MENU
key to exit the sensor
type selection menu.
Sensor Types
Sensor Range (typical)
IR8
0 – 20000 mg/l
IR15
0 – 10000 mg/l
IR40
0 – 1500 mg/l
IR100
0 – 200 mg/l
IR12LS
0 – 500 FTU
TT2000LA
0 – 20000 mg/l
TT2000LS
0 – 500 mg/l
TT10i/20i
0 – 20000 mg/l
TT2i/12i
0 - 500 mg/l
IL55/IL55BV2
0 – 5% SS
ST20
0 – 200mg/l
0 – 1500mg/l
0 – 10000mg/l
0 – 30000mg/l
NOTE: When the sensor type is changed, the sensor defaults for the new sensor are loaded and will over write
any settings that have been made with the previous sensor.
12.2 Select Display Range
The display range setting determines the range and resolution of the displayed measured value, a default range is
loaded when the sensor type is changed.
Range
Resolution
0 – 10.00
0.01
0 – 100.0
0.1
0 – 1000
1
0 – 10000
10
0 – 50000
100
167300IM-Issue 12 Issue Date 14/10/2014