STEP 4: (Optional)   
The  pump  hose  will  be  attached  to  rear  filter  panel.  Should  the  hose  come  off 
during  removal  of  rear  filter  panel  or  be  removed  for  servicing  the  filters,  care 
should be taken to re-attach the hose and snap lock clamp before replacing rear 
filter panel. 
   
IMPORTANT: The rotation of the snap lock clamp must be correct (see diagram 
above) to refit the rear filter panel assembly.       
 
 

----------------------------------------------------------- 

 
 
Filter Pads   
Visually check filter pads for damage or blockage. Gently hose down pads from 
both sides to remove any build up of salts, dust and pollen. In dusty areas more 
regular  cleaning  is  recommended.  Check  the  water  distributor,  making  sure  it  is 
clear  and  free  from  blockage.  Failure  to  do  so  may  lead  to  uneven  water 
distribution and therefore less efficient operation. 
 
Water Tank   
It  is  important  to  keep  the  water  tank  clean  and  free  from  sediment  and  algae 
growth. 
Using a small soft bristle brush, brush all surfaces in the tank while it is full of water 
Turn off the water inlet to the unit (an isolation valve should be fitted to the water 
inlet before the float valve or at the water supply faucet). Drain the tank by undoing 
the external overflow fitting lock nut and removing the overflow fitting. After refilling 
it may be necessary to repeat this procedure if the tank is very dirty.   
 
Water Distributor   
Check the water distribution system for blockage. Check the delivery tube for kinks 
or holes. 

Before Starting   

 

Always ensure that there is another open window or door through which the 
air  can  exhaust  to other  parts  of  the  house.  Refer  page  5  correct  operation 
and ventilation.   

 

Ensure that the filters are kept clean.   

 

Ensure that the water to the cooler is turned on.   

 

Ensure  the  plug  is  connected  to  a  220V  50Hz  single  phase  grounded 
appliance socket on the inside of the house and turned on.   

 

 

IMPORTANT.  After  the  first  10  hours  of  operation  in  COOL  mode,  the 
water  must  be  drained  from  the  unit  water  tank  to  remove  any  new 
product
 residuals. This process must be repeated after a further 10 hours 
of COOL
 mode operation. 

 

                                           

 

 

 

Press the button “

” in the standby, the Unit starts, the factory default 

setting: Fan works at minimum speed, cooling mode, Auto Swing works. The 

unit  is  turned  off  when  the  “

”  is  pressed,  the  temperature  is  shown 

after the unit is turned off. 

 

The  indicator  lights  shows  “Red”  color  when  the  unit  is  plugged  into 
electricity,  the  light  indicator  show  “Green”  when  the  unit  work  at  cooling 
mode. 

 

 

15 

 

Summary of Contents for WM 6.0

Page 1: ...Save Energy Save our Planet PARS EcoTech S L Malaga Spain info pars ecotech com www pars ecotech com PARS EcoTech WM 6 0 Evaporative Cooler Owner s manual...

Page 2: ...ter connection 12 Commissioning 12 Maintenance 13 Filter pads 15 Water tank 15 Water distributor 15 Water level Float valve 16 Electrical 16 Maintenance Planner 17 Specifications 18 Specifications Air...

Page 3: ...Do not throw these Instructions away Installations of this cooler in any manner not prescribed by these instructions could cause a safety issue and WILL void any warranty Use only with a 220v 50Hz si...

Page 4: ...openings in the room to be cooled approximately 05 square meter Open doors and windows will usually provide this as per the diagrams below Please note it is important for good ventilation that doors...

Page 5: ...n the tank by undoing the external overflow fitting lock nut and removing the overflow fitting After refilling it may be necessary to repeat this procedure if the tank is very dirty Water Distributor...

Page 6: ...in the indicator of remote control 3 Mode The cooler can be operated in either of 2 modes COOL or FAN When the cooler is running in FAN model press the button the unit will run in COOL mode and the c...

Page 7: ...ncy THIS MANUAL CONTAINS A 5 YEAR MAINTENANCE PLANNER TO USE IN CONJUNCTION WITH THESE INSTRUCTIONS See page 14 5 Drain Press button drain the unit aromatically turn off the motor water pump swing and...

Page 8: ...s as illustrated prior to fixing the cooler Water Connection Fit mains water supply line to the float valve installed The float valve connection is BSP Note Water connection line to float valve must b...

Page 9: ...ce as necessary C Check the condition of the filter pad Wash if pad shows heavy build up of minerals D Clean bleed nozzle Use the two Wall mate screws provided to fix the cooler to the outside of the...

Page 10: ...vel on top edge of rear filter panel Problem Solving PROBLEM PROBABLE CAUSE REMEDY Excessive humidity A Not enough air flow B Inadequate Exhaust A Increase fan speed B Provide more open area to exhaus...

Reviews: