INSTRUCTION REF: IN103
ISSUE NO. 6
DATE 19.10.11.
Page 7 of 17
TELEPHONE:
SERVICE (44) 01332 875665
FAX:
SERVICE (44) 01332 875536
Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT
www.parry.co.uk
MAINTENANCE INSTRUCTIONS
MAINTENANCE AND SERVICE MUST ONLY BE UNDERTAKEN BY
REGISTERED FITTERS.
Parry advise that regular annual maintenance should be conducted by a Gas
Safe registered engineer. This is essential to maintain safety and prolong life of
the appliance.
PLEASE NOTE THE LOW RATE ADJUSTER ON THE UNIT HAS BEEN
FACTORY SET AND SHOULD NOT BE ADJUSTED UNLESS BY A
QUALIFIED ENGINEER IN WHICH CASE THE LOW RATE ADJUSTER
SHOULD BE RE-SEALED.
To facilitate maintenance it is recommended that the fascia is removed. To do
this, take off the control knobs and remove 2 screws from the underside of the
fascia panel.
Remove the nut from the underside of the griddle plate. The plate can then slide
forwards and be lifted off after withdrawing thermostat phials from underside of
plate.
Thoroughly clean the burner and burner chamber.
Carefully clean the thermocouple probe, the ignitor, electrode and pilot jet.
Reconnect the gas supply and check for gas soundness.
Check that the flame safety device is operating by shielding the probe from the
pilot flame until the device operates.
Check that the spark ignites the gas.
Thoroughly clean the plate and fat chute, and drawer.
Replace the thermostat phial to its correct position and fasten the plate down to
the body by tightening the nut.
Refit fascia panel with the 2 screws and re-attach the control knobs.