Installation Instructions
GAS CONNECTION
Connection to the appliance is by ½” BSPT at the rear of the appliance. Pressure test point is
located at rear of appliance.
The low rate adjuster is factory set and sealed for natural gas. If a unit needs to be
converted a qualified engineer must reseal the low rate adjuster after conversion.
Remove all protective film before use.
Ensure whoever is operating the appliance is fully conversant with its operation and aware
of dangers involved in incorrect operation and cleaning, especially the danger of burns or
scalds from the cooking medium and hot surfaces of working areas.
These appliances are to be installed with sufficient ventilation to prevent the occurrence of
unacceptable concentrates of substances harmful to health in the room in which they are
installed.
Gas hoses used to connect the appliance to the gas supply must be of the correct
specification for the gas and pressure of the appliance. The gas hose must comply with the
national requirements in force, and be CE marked, of a metal braided construction suitable
for commercial catering equipment. The hoses should be periodically examined and
replaced as necessary
The tube or hose shall be fitted such that there are no sharp bends or torsional strain which
may cause damage or failure of the tube or hose, especially near the end fittings. Torsional
strain can be prevented by the use of internal unions, swivel joints, etc. The bend radius
should not exceed that stated by the Manufacturer. The hose should not touch the ground
and should be no longer than 1.5m long.
A manual valve should be positioned upstream of the tube or hose unless the connection
fitting incorporates a self-sealing quick release coupling.
Where a quick release coupling is used for horizontal travel such as in commercial catering
appliances it is advisable that the coupling is facing downwards to prevent the ingress of
debris and ensure the hose is formed in to a smooth curve.
All units should have a restraining cable fitted preventing the unit from being pulled away
from the wall and causing the gas hose to become disconnected accidentally.