PARRY PDGFP Installation Instructions Manual Download Page 3

 

INSTRUCTION REF: IN145            
ISSUE No.  2  
DATE 25.02.09 
Page 3 of 13 

 

 

 

www.parry.co.uk 

GAS CONNECTION  

The gas connection is ½” B.S.P.T. on the left hand side rear of the fryer. The supply pipe must not be less 
tha

n ½”, an easily accessible isolation cock should be fitted in the pipework as close as possible to the 

fryer. An approved flex may be used in conjunction with a straining cable. 

 

MODEL PDGF FRYER 

 

 

 

 

                         

 

USER INSTRUCTIONS 
 

The attention of the user is drawn to the current Gas Safety (Instructions and Use) Regulations in force. 
This appliance must be used in accordance with these, also the need for regular servicing which must be 
carried out by a competent and qualified person. 
 

SAFETY NOTE 
 

Some  parts  and  surfaces  of  this  appliance  can  get  hot  in  use.  It  is  the  responsibility  of  the  Kitchen 
Supervisor to inform and warn every user of this and to ensure the user wears any necessary protective 
clothing when operating the fryer. 
 

LIGHTING INSTRUCTIONS 
 
WARNING:  DO NOT LIGHT BURNERS WHEN THE PAN IS EMPTY 
 

1)

 

Open the compartment door, ensure the drain valves are closed and check the level of cooking oil  

      (between maximum and minimum markings). The oil required to fill the pan to the correct level is 12   
      litres per pan. 
 
2)

 

Turn on the gas supply. 

 

3)

 

Turn the thermostat to OFF position. 

 

4)

 

Press the pilot knob (A) in and rotate anti-clockwise to igniter position 

 

Ignite pilot. If pilot fails to ignite, repeat the procedure. 
 

5)

 

After the pilot is lit, hold knob in for 20-30 seconds to ensure pilot flame is fully established. 

 

6)   Release the knob and turn fully anti-

clockwise to ‘ON’ position. If appliance fails to operate, repeat   

      steps 3-5. The main burner is now controlled by the thermostat (B). 
 
6)

 

To operate burner, turn thermostat knob (B) to required temperature. 

 

NOTE: LIDS SHOULD NOT BE USED WHILST FRYING 

 

SHUT DOWN OF THE FRYER 
 

1)

 

When appliance is not required, turn thermostat (B) fully anti-clockwise to off position, this  will leave 
only the pilot lit ready for when the fryer is next required. 

 
2)

 

To turn the unit off completely, turn the thermostat fully anti-clockwise and the pilot knob (A) fully   

  clockwise. 

Summary of Contents for PDGFP

Page 1: ...INSTRUCTION REF IN145 ISSUE No 2 DATE 25 02 09 Page 1 of 13 www parry co uk INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS PARAGON GAS FRYER MODEL PDGF PDGFP...

Page 2: ...ensure the correct ventilation requirements are met Attention should also be drawn to the need for regular servicing In normal use parts of the catering equipment may become hot suitable precautions m...

Page 3: ...WARNING DO NOT LIGHT BURNERS WHEN THE PAN IS EMPTY 1 Open the compartment door ensure the drain valves are closed and check the level of cooking oil between maximum and minimum markings The oil requir...

Page 4: ...ill prolong the life of the oil CLEANING INSTRUCTIONS The appliance should be cleaned with hot water and a mild detergent DO NOT USE ABRASIVES 1 Isolate the appliance from the gas supply 2 Allow oil t...

Page 5: ...again Leave it for 30 seconds before repeating the 5 10 seconds cycle Continue to repeat until the fat has melted so that any remaining unmelted pieces are free floating then turn the thermostat to th...

Page 6: ...avoid splashing of the oil or fat and prevent the fish sinking and sticking to the base of the pan Cooking Chart the following chart is for guidance only Maximum basket load not to exceed 3 lbs FOOD...

Page 7: ...the temperature of the oil or fat as recommended by the supplier Do not overload the fryer Remove the crumbs or pieces floating on the surface of the oil When using frozen foods follow the food manuf...

Page 8: ...ions secure Yes No Is there gas at the point when holding control knob in the pilot position Tighten connection Yes Very little No Check overtemperature stat for open circuit Check supply Check supply...

Page 9: ...temperature stat operates Is the temperature over 220 C Yes No Does the control stat operate on temp rise when set point is low 100 C Replace control stat Yes No Check calibration of control stat See...

Page 10: ...7kw PROPANE GAS G31 37mbar 24 80kw BUTANE GAS G30 28mbar 24 80kw G25 25mbar 25 00kw G25 20mbar 24 00kw TOTAL GAS RATE NATURAL GAS G20 20mbar 2 45 M hr PROPANE GAS G31 37mbar 0 94 M hr BUTANE GAS G30...

Page 11: ...BUTANE GAS 28mb 11 2 W G Adjust governor if necessary Only leave burner on for a minimum amount of time to ensure fryer does not get too hot 4 Turn the thermostat to off and ensure both burners exting...

Page 12: ...fryer 2 Remove screws from mounting bracket 3 Remove the thermostat gland nut 4 Release thermostat phial from clip inside tank 5 Pull stat through tank there will be some resistance felt due to the pa...

Page 13: ...t in reverse order SPARES LIST PDGF FRYER No off PARTS DESCRIPTION PART No 2 MULTI FUNCTION GAS VALVE VALVE7000 2 PILOT ASSEMBLY C W ELECTRODE PILOT7000 2 SAFETY LIMIT THERMOSTAT TMSTL7000 2 THERMOCOU...

Reviews: