INSTRUCTION REF: IN166
ISSUE NO. 6
DATE - 21.03.16
Page 3 of 24
www.parry.co.uk
MODEL
P4BO
The products stated above are designed and built to comply with the latest
versions of the following standards:
BS EN 203-1
BS EN 203-2-1
BS EN 203-2-2
The products have been CE-marked in compliance with the
European Gas
Directive (90/396/EEC)
INSTALLATION INSTRUCTIONS
ALL APPLIANCES MUST BE FITTED AND OR CONVERTED BY A
REGISTERED INSTALLER, IN ACCORDANCE WITH CURRENT
REGULATIONS.
INSTALLATION
Before installation check data plate on rear of unit to ensure appliance is suitable
for gas supply available.
During installation provision must be provided for combustion air to the appliance
through base and rear of appliance. This should not be blocked at any time. This
appliance should be installed with sufficient ventilation to prevent the occurrence
of unacceptable concentrations of substances harmful to health in the room in
which it is installed.
POSITIONING
The appliance must not be installed on or against combustible surfaces
–
minimum clearances must be :
Rear
150mm (6”)
Sides
150mm (6”)
Hotplate to combustible material 1525mm (60”)
All local fire regulations should be observed.
It is recommended that the appliance be sited below a ventilating hood preferably
of the extractor type incorporating a grease filter.